Three-phase fire-limiting current protector (wall-mounted) 100-160A_SupplyPro Co., Ltd._Yongnuo Electrical (Leqing) Co., Ltd.
Yongnuo Electrical (Leqing) Co., Ltd. Track-mounted meters, electrical fire-limiting protective devices, power meters, multi-functional meters, track-mounted meters
Return to List

Three-phase fire-limiting current protector (wall-mounted) 100-160A

Three-phase current limiting protector, effectively overcoming the shortcomings of traditional circuit breakers and monitoring equipment, such as high short-circuit current, long time to interrupt short-circuit current, large arc sparks during short-circuit, and rapid restriction of short-circuit current at a microsecond speed during lifespan to protect the power lines at the end and branches of various electrical usage sites, including shopping malls, hotels, warehouses, residential areas, electric vehicle charging stations, and marketplaces.

Product Features

Short-circuit breaking capacity: 0.00015 seconds

Real-time current measurement

Fan design, to prevent overheating of equipment

Guide rail installation, enhance work efficiency

Application fields cover various sectors.

Feature Description

Fault protection feature: When the product malfunctions, a fault indicator is triggered, and the self-protection function is activated.

Overload Protection Function: Cuts off the overloaded circuit after 3 consecutive seconds of overload to prevent fire due to overload.

Short-circuit protection function: Cuts off the circuit power within 150 microseconds when a protected distribution circuit experiences a short circuit, preventing fires caused by the short circuit.

Real-time current measurement function: Measures the current magnitude in the protected distribution circuit in real time.

Communication Function: Supports connection to electrical fire monitoring equipment for remote monitoring.

Real-time temperature measurement feature: Measures the cable temperature in the protected distribution circuit in real time. If the cable temperature exceeds the set threshold, an alarm message is sent to the host computer, and the alarm status remains active until reset.


Technical Specifications

Technical SpecificationsIndex
Rated VoltageAC220V/50Hz
Work scheduleOn-site power supply, 24/7 operation
Power ConsumptionSelf-consumption power ≤ 3W (no load)
Baud rate9600 (default)
Communication MethodsRS485
Communication ProtocolMODBUS-RTU
Work EnvironmentWorkplaceAreas with weatherproof and dustproof conditions
Ambient Temperature-25℃~+50℃
Relative Temperature10% to 95% (non-caking)
Poster heightNo more than 5,000m

Dimensions and wiring diagram

Track-type: 155mm (L) x 108mm (W) x 70mm (D)



在线咨询
Hotline:17306773009
  • Product Introduction
  • Technical Parameters
  • Custom Selection

Three-phase current limiting protector, effectively overcoming the shortcomings of traditional circuit breakers and monitoring equipment, such as high short-circuit current, long time to interrupt short-circuit current, large arc sparks during short-circuit, and rapid restriction of short-circuit current at a microsecond speed during lifespan to protect the power lines at the end and branches of various electrical usage sites, including shopping malls, hotels, warehouses, residential areas, electric vehicle charging stations, and marketplaces.

Product Features

Short-circuit breaking capacity: 0.00015 seconds

Real-time current measurement

Fan design, to prevent overheating of equipment

Guide rail installation, enhance work efficiency

Application fields cover various sectors.

Feature Description

Fault protection feature: When the product malfunctions, a fault indicator is triggered, and the self-protection function is activated.

Overload Protection Function: Cuts off the overloaded circuit after 3 consecutive seconds of overload to prevent fire due to overload.

Short-circuit protection function: Cuts off the circuit power within 150 microseconds when a protected distribution circuit experiences a short circuit, preventing fires caused by the short circuit.

Real-time current measurement function: Measures the current magnitude in the protected distribution circuit in real time.

Communication Function: Supports connection to electrical fire monitoring equipment for remote monitoring.

Real-time temperature measurement feature: Measures the cable temperature in the protected distribution circuit in real time. If the cable temperature exceeds the set threshold, an alarm message is sent to the host computer, and the alarm status remains active until reset.


Technical Specifications

Technical SpecificationsIndex
Rated VoltageAC220V/50Hz
Work scheduleOn-site power supply, 24/7 operation
Power ConsumptionSelf-consumption power ≤ 3W (no load)
Baud rate9600 (default)
Communication MethodsRS485
Communication ProtocolMODBUS-RTU
Work EnvironmentWorkplaceAreas with weatherproof and dustproof conditions
Ambient Temperature-25℃~+50℃
Relative Temperature10% to 95% (non-caking)
Poster heightNo more than 5,000m

Dimensions and wiring diagram

Track-type: 155mm (L) x 108mm (W) x 70mm (D)



品牌: Yongnuo Electrical
Model: Customization supported
Region: National
Brand: Yongnuo Electrical
单价: 电议
最小起订Quantity:
供货总Quantity:
有效期至: 长期有效
最后更新: 2025-02-05 09:25

Core Custom Selection

24h Online Service

Submit your requirements for quick product recommendations

Service
Hotline
17306773009
 Click submit means you agree to《Service terms》《Privacy policy》