BWLK-FQXThe flame detection and alarm system, known as the fire shutdown alarm interlock device, is specifically designed and developed to meet the needs of industries such as petrochemical, metallurgical, coal chemical, and ceramic sectors.EquipmentThe product is equipped with a flame detector.Explosion-proof pressure switchFlammable Gas Detector, featuring flame extinction, gas under-pressure, and gas leakage detectionAlarmInterlock protection features, with simple operation, reliability, and easy maintenance, suitable for flame detection and shutdown, under-voltage, and leakage interlock alarms in various gas burners and oven loaders.
I. Function Overview:
This control box is explosion-proof, explosion-proof grade:ExdbebⅡBT4The control box is equipped withBWZJ-43-KUltraviolet flame switches, circuit breakersSwitched-mode power supplyControl modules, buttons, indicator lights, and other control components. Inside the box.BWZJ-43-KUltraviolet flame switches utilize our high-performance products, with electrical components sourced from renowned domestic brands to ensure reliable equipment operation. The system is manually operable./Automatic mode conversion with shutdown, gas under-pressure, and gas leakage interlock protection; in case of unexpected shutdown, gas under-pressure, or gas leakage during system operation.(The leak alarm interlock can be enabled or disabled according to process requirements via interlock jumper wires. That is, when the jumper wire is plugged into the socket, the system will only alarm for gas leaks without interlocking to close the gas valve; when the jumper wire is unplugged from the socket, the system will both alarm for gas leaks and interlock to close the gas valve simultaneously. At the time of product shipment, the jumper wire is plugged into the socket by default, and it is set to only alarm for gas leaks without interlocking to close the gas valve.At that time, it can be handled promptly.AlarmShut off the gas solenoid valve to ensure system safety, and may alsoManual/Automated Running SignalsFire SignalGas valve open signal, fireout fault signalUnder-voltageFaultSignal, LeaksFaultSignalFault alarm signalIn switch quantity form or485Interface (optional) uploaded to the host computer for ease of operationReal-timeSurveillance. This control system is simple, safe, and reliable to operate.
II. Main Technical Parameters:
1Main Technical Parameters:
■ Working Power Supply:220VAC/50Hz
■ Power Consumption:100W
Flame Response Time: Response to flame ≤1s
Engine shutdown response1~3s
Turn on the power switch on the box surface/Power indicator light (red) on
In manual run status, the manual run indicator light (green) is on.
In automatic operation mode, the automatic operation indicator light (green) is on.
Flame Response: Red indicator light illuminates upon flame detection
Engine Off Response: The engine off fault indicator (yellow) illuminates, with an audible and visual alarm activated.
Low-pressure response: The low-pressure fault indicator light (yellow) illuminates, and the audible and visual alarm sounds.
The leak fault indicator light (yellow) illuminates and the sound and light alarm sounds during gas leak response.
Output:1(Note: The Chinese character “燃” means "combustion" or "ignite" in English. Since there is no context provided, it's difficult to translate it accurately into a specific sentence. However, here are a few possible translations depending on the context:) - Combustion - Ignition - Flammability - CombustibleGasElectromagnetic Valve Power Supply AC220V /DC24V Each set
2IgniteGasA set of valve interlock signals (relay passive normally open contact, capacity)220VAC·3A)
3)Explosion-proof pressure switches and combustible gas detectorsPower Supply DC24V A set
4Manual OperationSignal Set (Passive Normally Open Relay Contact, Capacity)220VAC·1A)
5Automated OperationA set of signals (Relay passive normally open contact, capacity220VAC·1A)
6FireSignal Set (passive normally open contact of relay, capacity)220VAC·1A)
7Shut offFault Signal Set (Relay Passive Normally Open Contact, Capacity)220VAC·1A)
8)A set of under-voltage fault signals (relay passive normally open contact, capacity)220VAC·1A)
9LeakA set of fault signals (relay passive normally open contact, capacity)220VAC·1A)
10)FaultAlarmSignal Set (Relay Passive Normally Open Contact, Capacity)220VAC·1A)
11)485A set of interfaces (optional)
Ambient Temperature Usage: -20℃~80℃
■ Ex-proof rating: ExdbebⅡBT4