品牌: Orion Orlong
Order Number: 086030MD
Oxygen Consumption: 0.008 μg/h (mg/L) at 20℃
Description: Mini-DIN Connector
单价: 10009.00/Piece
最小起订Quantity: 1 Piece
供货总Quantity: 1000 Piece
有效期至: 长期有效
最后更新: 2024-04-02 08:58
 
详细Info

086030MD Application: Laboratory Measurement, Self-featured Stirring Paddle

Cable Length: 2 m

  Matching Host: Star Series Desktop

Sample low flow rate: 10 cm/second

Sample Temperature: 0 - 50°C

Electrolyte usage: 180 days

Response Time: Achieve 90% within 10 seconds, 95% within 15 seconds, and 99% within 1 minute

Attachment Model: Molding - 080515, Electrolyte - 080514, Maintenance Kit - 080513

  U.S.A. Thermo Orion Orielon Auto-Turbidimeter Dissolved Oxygen Electrode 086030MD

Oxygen Saturation Measurement Basics

· During laboratory measurement of dissolved oxygen, the solution to be tested must be stirred at a constant speed; when measuring outdoors, the water body must have a certain flow rate to ensure the rate of dissolved oxygen passing through the electrode membrane.

· The solution must not generate an electromagnetic field that interferes with measurement signals during stirring or flow to ensure the stability of measurement data.

· Oxygen sensors require a certain polarization time both before calibration and measurement.

Ensure that the main power supply is turned off before removing the oxygen sensor electrode for maintenance.

Order Number Description

08/05/13 Dissolved Oxygen Maintenance Kit (1 bottle of electrolyte, 1 sheet of polishing paper, 2 membrane sleeves)

  083005MD, 083010MD, 083025MD, 083060MD, 086030MD, 083005A, 083010A,083025A, 083060A,083005D, 086020A, 083150A, 083010F, 081010F, 081030F

080515 - 1 piece of casing

  083005MD, 083010MD, 083025MD, 083060MD, 086030MD, 083005A, 083010A,083025A, 083060A, 083005D, 086020A, 083150A, 083010F, 081010F, 081030F

081003 - 3 Membrane Sleeves

  080510MD, 081010MD, 081010

Electrolyte

  083005MD, 083010MD, 083025MD, 083060MD, 086030MD, 083005A, 083010A,083025A, 083060A, 083005D, 086020A, 083150A, 083010F, 081010F, 081030F,080510MD, 081010MD, 081010