Thermo Orion DO Desktop Meters VSTAR30 VESTAR DO/RDO Modules_SupplyPro Co., Ltd._Guangzhou Borletech Technology Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Guangzhou Borletech Technology Co., Ltd.

Orion / Eutech / Precisa / Techcomp (formerly Shanghai Jingke) / LabTech

Soule Star Diamond Member
Consultation Hotline
18680226663

News Center Co., Ltd.
  • No News

Product Categories

Contact Information
  • Contact person:王小姐
  • Telephone:18680226663
  • Mobile:18680226663

Home > SupplyPro Co., Ltd. > Thermo Orion DO Desktop Meters VSTAR30 VESTAR DO/RDO Modules
Thermo Orion DO Desktop Meters VSTAR30 VESTAR DO/RDO Modules
品牌: ORION/Orion
Installation Method: Fixed
Measurement Range: 0.00 to 90.00 mg/L
Measurement Accuracy: 0.01
单价: 电议
最小起订Quantity: 1 Piece
供货总Quantity: 999 Piece
有效期至: 长期有效
最后更新: 2024-04-03 08:47
 
详细Info

Thermo Scientific Orion Versa Star Pro DO Desktop Meter

Part Number: VSTAR30

Atmospheric Pressure Calibration 400 to 850 mmHg, auto operation with built-in barometer or manual input
Description Orion Versa Star Pro Desktop Measuring Instrument, with RDO/DO Module and Bracket
Output USB (2),RS232
Including Versa Star Pro meter, VSTAR-RD RDO/DO module, electrode bracket, universal power adapter, documentation CD, printed quick start guide, computer interface cable, and meter inspection certificate
Measurement Modes Dissolved Oxygen (expressed as % saturation or mg/L), along with temperature and atmospheric pressure.
Sensor Type RDO Optical Dissolved Oxygen Sensor or Polarographic Dissolved Oxygen Sensor
Scope (Extremum Spectral Oxygen Dissolved, DO) 0.00 to 90.00 mg/L
Percent Saturation Range (Polarographic DO) 0.0 to 600.0% Saturation
Resolution (Polarographic Oxygen Saturation) 0.01,0.1 mg/L
Accuracy (Polarographic Oxygen Saturation) ±0.2 mg/L or ±2% of the reading, whichever is greater
Pressure Range 400 to 850 mmHg
Calibration Mode Saturated air with water vapor, saturated water with air, manual (Winkler titration), zero point
Temperature Range (Metric) -5.0°C to +105.0°C
Resolution (Temperature) 0.1°C (0.1°F)
Accuracy (Temperature) ± 0.1°C
Temperature Selection Automatic (including ATC temperature probe)
Temperature electrode calibration 1. Temperature offset calibration
Display Type Color graphic LCD display with user-customizable options
Backlight Options Is
Storage Non-volatile memory for storing data records, calibration records, and instrument settings
Data points 2000 (including date and timestamp)
Log Function Types Automatic data recording with measurement modes including automatic reading, timed reading, and single trigger; Manual data recording
Data Management Details Transmit data points, range data points, or all data points to a printer or computer
Alarm Output Setpoint alarm, High/Low limit alarm, Calibration due alarm
Input 9 Pin MiniDIN (RDO optical or polarographic DO sensor, with built-in temperature probe), two stirrer input terminals (stirrer probe)
Certification/Compliance CE, TUV 3-1, FCC A class
IP Protection Rating IP-54
AC/DC Power Adapter Universal power adapter (Part No. STARA-PWR), 50-60 Hz, 100-240 VAC
Dimensions (Length x Width x Height) 28 cm x 24 cm x 10 cm (11" x 9.5" x 3.9"), Module L and H increase ≤ 2 cm (0.8")
Weight (Metric) 1.2 kg, each module adds 0.2 kg
Weight (Imperial) 2.5 lb., each module adds 0.5 lb.
Relative Humidity Range 5% to 85%, non-condensing environment
Warranty period Meters and Modules - 3-Year Warranty
Percent Saturation Range Polarographic DO 0.0 to 600.0% Saturation
Keyboard Digital keypad with menu-specific function keys and dual-purpose scroll/speed keys
Language English, Spanish, French, Italian, German, Chinese, Portuguese, and Korean
Accuracy (RDO) ± 0.1 mg/L (max 8 mg/L), ± 0.2 mg/L (8-20 mg/L), ± 10% of the reading (max 50 mg/L)
Scope (RDO) 0.00 to 50.00 mg/L
Method 10/Channel
Percent Saturation Relative Accuracy (RDO) ±2% Saturation ≤ 200% Saturation, ±10% Saturation > 200% Saturation
Percent Saturation Resolution (Polarographic DO) 0.1, 1% Saturation
Percent Saturation Range (RDO) 0.0% to 500.0% Saturation
Percent Saturation Relative Accuracy (Polarographic DO) ±2% saturation or ±2% reading, whichever is greater
Percent Saturation Resolution (RDO) 0.1, 1% saturation
Rated Power Direct Current Input: 9 VDC, 1 A
Power Supply Universal AC Adapters (inclusive)
Pressure Resolution 0.1mmHg
Probe Type RDO Optical Dissolved Oxygen Probe, Polarographic Dissolved Oxygen Probe, Stirrer Probe (sold separately)
Channel 4 - Customizable Modules
Resolution (RDO) 0.01,0.1 mg/L
Salinity factor 0.0 to 45.0 ppt, automatically calibrated through manual input of sample salinity
Stability Choose from Fast, Medium, Slow, or Smart Stability settings; select On or Auto Smart Averaging settings.
Operating Temperature (Imperial) 41°F to 113°F (Ambient Temperature)
Operating Temperature (Metric) 5°C to 45°C (Ambient Temperature)
Accuracy (barometer) ± 6 mmHg

Thermo Scientific Orion Versa Star Pro Benchtop Meter is designed to effortlessly meet the demands of your challenging applications. With its extensive features and capabilities, it allows for optimized setup of your metering system to accommodate evolving requirements. The Orion Versa Star Pro Benchtop Meter offers interchangeable measurement modules, supporting multiple users with 4 independent channels for customized solutions to their specific needs. Text size is adjustable for easy viewing of measurement results on the high-quality color display. Eliminate guesswork in meter calibration with setup instructions in multiple local languages. Enjoy quick and simple data entry with a digital keypad.

Through the screen display, use the stability indicator to ascertain the exact time when the measurement results are ready.

The following optional reading modes are included: Automatic reading maintains stable readings, continuous reading displays reading changes, timed reading records data at specific time intervals, and single reading holds the reading after a specific waiting time is reached.

Sound alarm automatically notifies upon reaching the set offset value, upper/lower limit values, and calibration time interval.

Each channel can utilize 10 password-protected methods for easy access, updates, and preference measurement setting changes.

Two stirrer probes controlled by the meter can uniformly mix the solution; the probes are easy to locate and can be quickly rinsed during breaks in sample processing.

Data logging and date/time tagging can be performed for up to 2,000 measurement sets, along with optional electrode ID, sample ID, and account ID.

Calibration records can store the 30 most recent calibration results for each parameter.

Check the active calibration log simultaneously with the reading to ensure measurement integrity.

The measuring instrument's non-volatile memory can retain data and settings even when power is disconnected.

The measuring instrument software can transmit data to the computer via USB or RS232 connection.

IP54 rated housing for dust and splash protection; wall mounting available for limited desk space.

The meter includes CE, TUV and FCC A Class certifications, as well as a 3-year replacement warranty.

Including Orion Versa Star RDO/DO measurement module:

Utilize the Orion RDO Optical DO Probe or the Orion Polarographic Dissolved Oxygen (DO) Probe, along with the sensor auto-identification feature, to measure dissolved oxygen levels (expressed as saturation percentage or mg/L) and temperature.

Calibrate dissolved oxygen using saturated air with moisture, saturated water, custom values (Winkler titration), and zero point options.

The system automatically compensates for dissolved oxygen readings using ATC temperature, manual salinity input, and an internal barometer (atmospheric pressure measurement).

Customizable measurement results to display calibration history or simplify the display of high dissolved oxygen readings.

System Access Features

The Orion Versa Star Pro meter supports system access features, designed to prevent unauthorized access to various meter functions (including date/time settings, data recording, and calibration logs), ensuring data integrity. To accommodate changes in laboratory requirements, the system access feature can be easily enabled or disabled, providing better operational flexibility and ease of use. With system access enabled, system administrators and up to 10 user accounts can customize access to instrument settings, measurement settings, calibration, and logs. Password protection is used to secure selected meter functions while allowing convenient access to other features for all users. The system access feature allows you to customize meter access permissions to meet your specific security and data reporting needs.

Disclaimer of Use Limitation for Internal Research: Any restrictions on the buyer's use of the product for internal research do not apply to the products listed on the web pages related to this statement.