The AKT series cabinet-type high-frequency switching power supply boasts high performance, stability, reliability, compact size, and light weight. It also features various essential protection functions such as overvoltage, current limiting, and short-circuit protection. You can pre-set voltage, current, and overvoltage protection values before loading, and easily check the set parameters during operation. The operation is simple and convenient.

Product Features:
Voltage and Current Presets: The panel features preset buttons for pre-setting voltage and current values.
Voltage and Current Stabilization: Continuously adjustable from zero to rated values, with automatic switching between voltage and current stabilization
Over-voltage Protection: The machine locks after protection and automatically unlocks upon restart.
Overcurrent Protection: Rated current output overload protection, short circuit protection (output is shut off after short circuit, optional)
Short-circuit Protection: Allows for long-term short-circuit or short-circuit startup in any state
Short Circuit Alarm: Sound and light alarm when the output is short-circuited.
Pulse operation: Can be equipped with a timer controller to form a DC pulse power supply (optional)
Communication: Standard RS485 communication interface
Special specifications and features are customizable.

Specification parameters
Communication Input | Input: AC380V±10% 50Hz±10% |
Direct Current Output | Output: Voltage approximately0-10000V,Current approximate0-3000APower≤60KW |
2Steady voltage accuracy | Source Effect≤0.5%Rated value (only due to the change in input source voltage)-5%~10%Output voltage change rate caused by time Seasonal Float≤0.5%Rated value (only due to the power supply continuous operation time being greater than)8Output voltage change rate caused by the hour. Warm漂移≤0.1%/℃±2A unit (within 30 minutes) (due solely to the change rate of output voltage caused by environmental temperature fluctuations within the power supply operating temperature range) Load Effect≤0.5%Rated Value±2Individual character (only due to the change rate of output voltage when the output current varies from zero to the rated value) |
3Flow Rate Stability Precision | Source Effect≤ 0.1%Rated value (only due to input voltage source changes)-5%~10%Voltage output rate of change due to time Seasonal Floating≤ 0.3%Rated value (only due to the power supply continuous operation time greater than)8Rate of change of output voltage caused by the hour-time factor) Warm漂移≤ 0.1%/℃±2Character (within 30 minutes) (only due to the output voltage variation rate caused by environmental temperature changes within the power supply operating temperature range) Load Effect:≤1%Rated Value±2Individual character (only due to the change rate of output current when the output voltage varies from zero to the rated value) |
4Wavy patternr.m.s) | ≤0.5%+50mVOutput: Maximum voltage |
5Efficiency | ≥ 90%(Measured at rated output) |
6Output Voltage Adjustment Range | Approximate0 ~10000VContinuous Adjustment |
7Output Current Adjustment Range | Approximate0 ~3000AContinuous Adjustment |
8Output Voltage and Current Display Method | LCDOr digital tube display |
10Output Voltage, Current Settings | Rotary encoders and key settings, customizable with touch control. |
12Protection Method | 1Short circuitOvervoltage, overcurrent, overheating protection, with corresponding fault indication. 2Main TransformerIGBTModules and rectifier diodes are cooled by a heat dissipation fan. |
13Working Method | Continuous operation at full capacity |
14Display Error | Voltage Meter≤ ±0.5%±1Unit (Measurement Range)10%~100Rated Value (%) Ammeter≤ ±1%±1Unit (Measurement Range)10%~100Rated Value (%) |
15Chassis Dimensions(Reference Dimensions) | 600*1000*650Please provide the Chinese content you would like translated into American English.*High*Deepmm) |
16Application Environment | 1Usage Location: Indoor Use 2Temperature:-20℃~40℃ ; 3Relative Humidity:≤80% |