The AKT series 3U high-frequency switching power supply boasts high performance, stability, reliability, compact size, and light weight, and is equipped with essential protection functions such as overvoltage, current limiting, and short-circuit protection. Voltage, current, and overvoltage protection values can be pre-set before loading, and all set parameters can be checked at any time during operation. The operation process is simple and convenient.

Product Features:
Voltage and Current Presets: The panel features preset buttons for pre-setting voltage and current values.
Voltage and Current Stabilization: Continuous adjustment from zero to rated voltage and current values with automatic voltage and current stabilization switching.
Overvoltage Protection: The machine will automatically lock after protection and unlock automatically when restarted.
Overcurrent Protection: Rated current overload protection, short circuit protection (output shutdown after short circuit, optional)
Short-circuit Protection: Allows for long-term short-circuit or short-circuit startup in any state
Short Circuit Alarm: Audible and visual power alarm when an output short circuit occurs.
Pulse Operation: Can be configured with a timer controller to form a DC pulse power supply (optional)
Communication: Standard RS485 communication interface
Special specifications and features are customizable.

Specs and Parameters
Communication Input | Input:AC220VOrAC380V±10% 50Hz±10% |
Direct Current Output | Output: Voltage Approx0-1000V,Current approximates0-300A Power≤15KW |
2Stabilized Voltage Accuracy | Source effect≤0.5%Rated value (only due to input voltage variations)-5%~10%Output voltage rate of change due to timing Seasonal漂移≤0.5%Rated value (only due to the continuous operating time of the power supply being greater than)8Hourly voltage output change rate due to hour increments Warm漂移≤0.1%/℃±2Unit (within 30 minutes) (only due to the output voltage change rate caused by environmental temperature change within the power usage environment temperature range) Load Effect:≤0.5%Rated value±2Character (only due to the output voltage change rate caused by the output current varying from zero to the rated value) |
3Flow Stabilization Accuracy | Source Effect≤ 0.1%Rated value (only due to input voltage source variation)-5%~10%Output voltage change rate caused by time. Seasonal Float≤ 0.3%Rated value (only due to continuous power-on time being greater than)8Output voltage change rate caused by hours Warm漂移≤ 0.1%/℃±2A character (within 30 minutes) (only due to the rate of change of output voltage caused by environmental temperature changes within the power supply environment temperature range) Load Effect:≤1%Rated Value±2Individual character (only due to the change rate of output current when the output voltage varies from zero to the rated value) |
4Wavinessr.m.s) | ≤0.5%+50mVOutput at Maximum Voltage |
5Efficiency | ≥ 90%(Rated Output Measurement) |
6Output Voltage Adjustment Range | Approximate0 ~1000VContinuous Adjustment |
7Output Current Adjustment Range | Approximate0 ~300AContinuous Adjustment |
8Output Voltage and Current Display Method | LCDOr digital tube display |
10Output Voltage, Current Settings | Rotary encoders and button settings, customizable with touch control. |
12Protection Method | 1Short circuitOvervoltage, overcurrent, overheat protection, with corresponding fault indication; 2Transformer mainIGBTModule and rectifier diodes are cooled with a heat dissipation fan. |
13Work method | Continuous full load operation |
14Display Error | Voltage meter≤ ±0.5%±1Unit (Measuring Range)10%~100Percent rated value Ammeter≤ ±1%±1Unit (Measurement Range)10%~100Rated Value (%) |
15Chassis dimensions | 430*133*550Please provide the Chinese content you would like translated into American English.*High*Deepmm) |
16Application Environment | 1Application: Indoor Use 2Temperature:-20℃~40℃ ; 3Air Humidity:≤80% |