The AKT series 2U high-frequency switching power supply boasts high performance, stability, reliability, compact size, and lightweight. It also features essential protection functions such as overvoltage, current limiting, and short-circuit protection. Voltage, current, and overvoltage protection values can be pre-set before loading, and all set parameters can be easily checked during operation. The operation process is simple and convenient.

Product Features:
Voltage and Current Preset: The panel features preset buttons for pre-setting voltage and current values.
Voltage and Current Stabilization: Continuous adjustable from zero to rated value, automatic switching between voltage and current stabilization
Overvoltage Protection: The machine will automatically lock after protection and unlock automatically when restarted.
Overcurrent Protection: Rated current output overload protection, short-circuit protection (output shutdown after short-circuit, optional)
Short Circuit Protection: Allows for long-term short circuit or short circuit startup in any state.
Short Circuit Alarm: Sound and light alarm when the output is short-circuited.
Pulse operation: Can be equipped with a timer controller to form a DC pulse power supply (optional)
Communication: Standard RS485 communication interface
Special specifications and features are available for customization.

Specs and Parameters
Communication Input | Input:AC220VOrAC380V±10% 50Hz±10% |
DC Output | Output: Voltage Approx.0-1000V,Current Approximation0-200A Power≤10KW |
2Stabilized Voltage Accuracy | Source Effect≤0.5%Rated value (only due to the change in input source voltage)-5%~10%Output voltage change rate caused by time. Seasonal Fluctuations≤0.5%Rated value (only due to the power supply continuous operation time being greater than)8Output voltage change rate caused by the hour time Warm漂移≤0.1%/℃±2Character (within 30 minutes) (only due to the output voltage change rate caused by environmental temperature changes within the power supply operating temperature range) Load Effect≤0.5%Rated Value±2Individual character (only due to the output voltage change rate when the output current changes from zero to the rated value) |
3Flow Regulation Accuracy | Source Effect≤ 0.1%Rated value (only due to input voltage source variation)-5%~10%Output voltage change rate caused by time Seasonal漂移≤ 0.3%Rated value (only due to continuous power-on time exceeding)8Output voltage change rate caused by the hour timing Warm漂移≤ 0.1%/℃±2Character (within half an hour) (only due to the output voltage change rate caused by the change of environmental temperature within the power usage environmental temperature range) Load Effect:≤1%Rated Value±2Individual character (only due to the change rate of output current when the output voltage varies from zero to the rated value) |
4Wavinessr.m.s) | ≤0.5%+50mVOutput at the highest voltage |
5Efficiency | ≥ 90%(Measured at rated output) |
6Output Voltage Adjustment Range | Approximate0 ~1000VContinuous adjustable |
7Output Current Adjustment Range | Approximate0 ~200AContinuous Adjustment |
8Output Voltage, Current Display Method | LCDOr digital tube display |
10Output Voltage, Current Settings | Rotary encoders and button settings, customizable touch control. |
12Protection Method | 1Short circuitOvervoltage, overcurrent, overheating protection, with corresponding fault indication. 2Main transformer,IGBTModular rectifier diodes are cooled with a heat dissipation fan. |
13Work Method | Continuous full load operation |
14Display Error | Voltage meter≤ ±0.5%±1Individual Characters (Measurement Range)10%~100Rated Value (%) Ammeter≤ ±1%±1Unit (Measurement Range)10%~100Rated Value (%) |
15Case Dimensions | 430*88*550(Wide)*High*Deepmm) |
16Application Environment | 1Usage: Indoor Use 2Temperature:-20℃~40℃ ; 3Air Humidity:≤80% |