Lab Water Quality Tester Finds Industry-Wide Application
2024-09-02
The multi-parameter water quality analyzer in our lab is capable of simultaneously detecting and analyzing multiple water quality parameters such as COD, ammonia nitrogen, total phosphorus, total nitrogen, turbidity, and suspended solids. The device provides the analysis results for these parameters, enhancing efficiency and reducing laboratory costs. Utilizing optical fiber detection technology, the measured values are accurate. It offers rapid analysis of water samples and delivers stable, reliable test results, serving as a data basis for water quality monitoring and assessment. Equipped with an automated control system, operations can be automated through pre-set programs. Operators simply need to insert the water sample to be tested, set the relevant parameters, and the instrument will automatically complete the sample processing, analysis, and data recording, significantly increasing work efficiency. The analysis results can be saved and exported for further data processing and analysis, allowing users to view and manage data at any time and place.



1. *Sample Testing Station:3An independent testing station1 Colorimeter Detection Position,2A Colorimetric Cell Detection Position
2. Display: 7-inch color LCD touch screen、8 Touch-Sensitive Function Modules
3. Sample Input Device: Automatic Multi-Channel Detection Device(Concentration Direct-Read)
4. Detection Method:360-degree rotationColorimeter Testing(Pre-Made Reagents)Colorimetric dish testing(Solid Reagents)
5. Optical Inspection System: Fiber Optic Inspection System
6. *Measurement Project:COD, Ammonia Nitrogen, Total Phosphorus, Total Nitrogen, Turbidity, ColorimeterSuspending MatterHeavy metalsOver 50 indicators
7. Measurement Range:COD (2-20,000 mg/L), Ammonia Nitrogen (0-150 mg/L), Total Phosphorus (0-100 mg/L), Total Nitrogen (0-100 mg/L, Turbidity (0.5-)2500NTU)、Suspended Solids0-1500mg/L)...
8. Light Source:Import12V/20W Halogen Bulb (up to 100,000+ hours)
9. Accuracy in Detection:≤±5%
10. Wavelength Accuracy:±1nm
11. Wavelength Range:340-900nm
12. Wavelength Half-Width:4nm