An automated control system ensures the operation of the liquid controller or high, medium, and low electrode probes to regulate the pump's on/off, water supply duration, and heating during the furnace's operation. As the steam output continues, the top steam pressure set by the pressure relay decreases with the furnace water level. When the level is low (mechanical) or medium (electronic), the pump automatically refills water; it stops refilling when the level reaches high. Simultaneously, the electric heating tube in the furnace continues to heat, producing steam continuously. The steam pressure value is immediately displayed on the gauge on the panel or above the top. The entire process is automatically indicated by indicator lights.
News Center Co., Ltd.