Olympus/OLYMPUS High Temperature and Corrosion Thickness Gauge with Single Crystal and Double Crystal Function, Model 45MG

产品Price 15000.00/Set

最小起订Quantity:1 Set 供货总Quantity: 10000 Set

用手机扫描二维码直达商品手机版
MobileView details
Location:
Shanghai
有效期至:
长期有效
最后更新:
2022-11-30 17:14

Recommended Products

猜你喜欢

Product Details

45MGUltrasonic Thickness Gauge:Easy to operate, sturdy, and reliable in performance


 The 45MG instrument is a high-end ultrasonic thickness gauge equipped with various standard measurement features and software options. This uniquely designed instrument is compatible with all Olympus dual crystal and single crystal thickness probes, serving as an innovative machine that combines all solutions in one for almost all thickness measurement applications.

Standard Features

 The 45MG instrument, when used with the basic configuration, is an easy-to-understand and learn, user-friendly thickness gauge. Operators can master the most common thickness measurement applications after undergoing basic training. However, once the 45MG instrument is upgraded with optional software options and probes, it becomes an extremely advanced thickness gauge capable of applications that typical entry-level instruments cannot perform. Moreover, most options can be purchased separately at the time of instrument purchase or at a later date as needed.

  •  With allOlympusDual crystal probe compatible, capable of measuring the thickness of internally corroded metals

  •  Minimum Value/Value Model

  • Two alarm modes

  • Difference Mode

  • Time-basedBScan

  • Reduction rate

  • Gain Adjustment (Standard, High, Low)

  • Password-locked Instrument Lock


 45MG instrument with optional rubber sleeve and stand

 

Ability to withstand harsh environments

  • Durable and robust, designed to meet IP67 standards.

  • Explosive Atmosphere: Safe operation is permitted in explosive atmosphere environments as specified in Section 500, Division 2, Group D of the National Fire Protection Association (NFPA 70) standards, and has passed the tests as stipulated in Program I of MIL-STD-810G Method 511.4.

  • Impact Resistance Test: Passed the testing as specified in MIL-STD-810G Method 516.5 Procedure I, with 6 cycles per axis, 15 g, 11 msec half-sine wave.

  • Vibration Resistance Test: Passed the test according to Appendix C, Figure 6 of MIL-STD-810G Method 514.5, with general exposure of 1 hour per axis.

  • Broad operating temperature range

  • Optional rubber protective sleeve with stand

User-friendly design philosophy

  • Simple key area, operable with either right or left hand

  • A straightforward and easy-to-navigate interface for accessing most features directly

  • Utilize storage with built-in MicroSD card and removable MicroSD card options

  • USB communication port

  • Optional alphanumeric data logger capable of storing 475,000 thickness readings or 20,000 waveforms

  • Default or Custom Single Crystal Probe Settings (Optional)

  • Instrument locked with password protection method

  • Color transreflective QVGA display with indoor and outdoor color settings, offering excellent clarity

 

                                 
Outdoor Display Settings, Optional A Scanning ModeIndoor Display Settings, Optional A Scanning Mode

 

Measure corrosion on workpieces using a dual crystal probe

 A primary application of the 45MG thickness gauge is to measure the remaining thickness of corroded or eroded pipes, fittings, boxes, pressure vessels, ship hulls, and other structures. The most commonly used probe in these applications is the dual crystal probe.

  • Automated probe identification feature for standard D79X series dual crystal probes

  • A dual echo warning is issued when dual echoes occur during the calibration process.

  • Echo-to-echo/penetrating coating options can measure surfaces with paint and coatings

  • High-Temperature Measurement: Temperatures up to 500 °C


 


45MG thickness gauge paired with D932 series probes (D790, D790-SM, D790-RL, and D790-SL) is an ideal choice for measuring high-temperature materials (up to 500 ºC) and provides stable thickness readings. The 45MG's zero-point compensation feature enhances accuracy when measuring on high-temperature surfaces by compensating for temperature variations caused by probe delay blocks due to thermal drift.

 

Penetrating Coating Technology

 

Measure the actual thickness of metal using a single-bottom surface echo. This technique can separately display the thickness of the metal and the coating. Both thicknesses are adjusted according to their respective correct material sound velocities. Therefore, there is no need to remove the paint layer and coating on the surface to obtain the thickness of the metal. The penetration coating measurement technology utilizes D7906-SM, D7906-RM, and D7908 dual crystal probes.

                                       

Display coating thickness and steel material thickness through the coating mode (wave option is not activated)Displayable Optional Waveform Penetration Coating Mode

Key Technical Parameters

Measurement

Dual Crystal Probing Mode

The precise delay from the激励 pulse to the first echo.

Automatic Echo to Echo (optional)

The time interval between two consecutive bottom surface echoes, excluding the thickness of the paint or coating layer.

Penetration Coating Measurement (Optional)

Measure the actual thickness and coating thickness of metal using a single bottom surface echo (with D7906-SM and D7906 probes)

Single Crystal Probe Measurement Mode (Optional)

Pattern 1: Time interval between the incentive pulse and the first bottom surface echo.

Pattern 2: Time interval between the delayed block echo and the first bottom surface echo (using a delay block or water immersion probe)

Mode 3: Time interval between the adjacent bottom surface echoes following the first surface echo, after the激励 pulse (using a delay block probe or a water immersion probe).

Thickness range

0.080 mm~635 mm (0.003 in. to 25.0 in.) varies depending on material, probe, surface condition, temperature, and selected configuration (single crystal option required for full measurement range)

Material Sound Velocity Range

0.508 mm/μs~18.699 mm/μs(0.020   in./μs~0.7362 in./μs)

Resolution (optional)

Low Resolution: 0.1 mm (0.01 inch)

Standard Resolution: 0.01 mm (0.001 inch)

Single Crystal Options: 0.001mm (0.0001 inch)

Probe Frequency Range

Standard: 2.25 MHz to 30 MHz (-3 dB) High Penetration (Single Crystal Option): 0.50 MHz to 30 MHz (-3 dB)

Standard Specifications

Operating Temperature Range

-10 °C~50 °C(14 °F~122 °F)

Keyboard

Sealed keyboard with color-coded function keys, featuring tactile and auditory feedback

Casing

Impact-resistant, waterproof housing with sealed gaskets; interfaces on the housing are sealed. Design complies with IP67 standard.

Dimensions (Width x Height x Depth)

Overall Dimensions: 91.1 mm x 162 mm x 41.1 mm

Weight

430.9Please provide the Chinese content to be translated into American English.

Power Supply

3AA Battery/USB Power Supply

Battery Operating Time

3AA Alkaline Battery: 20-21 hours

3AA NiMH battery: 22-23 hours

3AA Lithium-ion Battery: 35 to 36 hours

Standard

Design complies with EN15317 standard

Show

Color-Transmitting QVGA Display

LCD display, screen size: 54.61mm x 41.15mm

Detector

Full Wave, RF Wave, Positive Half Wave, Negative Half Wave (Waveform Options)

Input/Output

USB

2.0From the interface

Storage Card

Capacity: 2GB removable MicroSD card

Built-in data recorder (optional)

Data recorder

45MGIdentify, store, retrieve, clear, and transfer thickness readings, waveform images, and instrument configuration information via USB or MicroSD card.

Capacity

475000A thickness measurement reading, or 20,000 waveforms with thickness values

File Name and ID Code

32Filename with 20 alphanumeric characters

File Structure

6A standard or customized file structure for a specific application

Report

Aboard report summarizes data statistics and minimums/valuations

      



询价单
主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  
 点击确定代表您同意《服务条款》《隐私政策》
 
 Click submit means you agree to《Service terms》《Privacy policy》

Phone Consultation

Consultation Phone:
18019490612

Back to Top