Compensating wire K-type ZR-KC-FVP-2*1.5 thermocouple sensor temperature measurement extension wire

Detailed Explanation of Thermocouple Compensation Wire, Structure and Definition: Thermocouple compensation wire, commonly referred to as compensation wire, is typically composed of alloy wire, insulation, sheath, and shielding layer. Within a certain temperature range (including room temperature), it consists of a pair of insulated wires with a nominal electromotive force (emf) value identical to that of the matched thermocouple. These wires are used to connect the thermocouple to the measuring device to compensate for the temperature variations at the connection point, thus reducing errors.

Two: Using compensation wires between thermocouples and measuring devices has two advantages:

1. Enhance the physical and mechanical properties of thermocouple temperature measurement lines. Using multi-strand cores or small-diameter compensating wires can improve the flexibility of the line, facilitate wiring, and also adjust the line resistance or shield external interference.

2. Reduce measurement line costs; when the thermocouple is far from the measuring device, the use of compensating cables can save a significant amount of thermocouple material, especially when using precious metal thermocouples, where the economic benefits are even more pronounced.



III. Terms and Symbols:

(1) Extended Compensation Wire: Also known as extended wire, the extended compensation wire has the same nominal chemical composition of the alloy wire and electromotive force (EMF) nominal value as the thermocouple it is paired with. It is denoted by the letter "X" appended after the thermocouple type number, e.g., "KX" indicates an extended compensation wire for a K-type thermocouple.

(2) Compensation Compensation Wire: Also known as Compensation Wire, this type has an alloy wire with a nominal chemical composition different from that of the thermocouple it is paired with. However, its electromotive force value is the same as the nominal value of the thermocouple's electromotive force at 0-100℃ or 0-200℃. It is indicated by the letter "C" appended after the thermocouple type number, such as "KC". Different alloy wires can be used for the same type number thermocouple, distinguished by additional letters, like "KCA", "KCB". Currently, it is not widely used.

(3) Allowance: The allowance for thermocouple compensation wires is due to the large deviation caused by the compensation wire in the measurement system. This value is expressed in microvolts, and the size of the allowance is divided into precision grade and ordinary grade.

(4) Symbols: S - indicates precision grade thermocouple compensation wire. No letter is marked for general grade compensation wire; G - indicates general use compensation wire; H - indicates heat-resistant compensation wire; R - indicates compensation wire with multi-strand cores. No letter is marked for compensation wire with a single strand core; P - indicates compensation wire with a shielding layer; V - indicates insulation or sheath made of polyvinyl chloride (PVC); F - indicates insulation made of polytetrafluoroethylene; B - indicates sheath made of non-glass fiber material.

KX-HA-FFRP Fluoroplastic烯绝缘 and sheath copper wire braided overall shield precision K degree thermocouple compensation flexible cable

KX-HA-FPFP Fluoroplastic Insulated and Sheathed Copper Wire Braid Screen Summation Precision K Class Thermocouple Compensation Cable

KX-HA-FPFRP Fluoroplastic Insulated and Sheathed Copper Wire Braid Screen Summation Precision Class K Thermocouple Compensation Flexible Cable

KX-HA-FVP Fluoroplastic烯绝缘 Polyvinyl Chloride sheath Copper wire braid Full shield Precision Grade K Thermocouple Compensation Cable

KX-HA-FVRP Fluoroplastic烯绝缘PVC sheath copper wire braided overall shield precision grade K thermocouple compensation flexible cable

KX-HA-FPVP Fluoroplastic Insulated PVC Sheathed Copper Wire Braided Screened Compensation Cable for Precision Class K Thermocouples with K Type Tolerance

KX-HA-FPVRP Fluoroplastic insulated polyvinyl chloride sheath copper wire braided screen combined shield precision K type thermocouple compensating flexible cable

KX-HA-FGP Fluoroplastic烯绝缘 Silicone rubber sheathed Copper wire braided Overall shielded Precision Class K Thermocouple Compensation Cable

KX-HA-FGRP Fluoroplastic烯 Insulated Silicone Rubber Sheath Copper Wire Braid Total Shield Precision Grade K Thermocouple Compensation Flexible Cable

KX-HA-FPGP Fluoroplastic Insulated Silicone Rubber Sheath Copper Wire Braid Screen Summation Shielded Precision Class K Thermocouple Compensation Cable

KX-HA-FPGRP Fluoroplastic Insulated Silicone Rubber Sheath Copper Wire Braid Screen Summation Shield Precision Class K Thermocouple Compensation Flexible Cable

KX-FP3F Fluoroplastic Insulated Aluminum/Plastic Composite Tape, Shielded Fluoroplastic Sheathed Compensation Cable for Standard Grade K Type Thermocouples

KX-FP3FP3 Fluoroplastic Insulated Aluminum/Plastic Composite Tape, Shielded and Overall Shielded Fluoroplastic Sheath, Standard Grade K Type Thermocouple Compensation Cable

KX-FFP3 Fluoroplastic Insulated Fluoroplastic Sheathed Copper Wire Braided Aluminum/Plastic Composite Tape Overall Shielded General Grade K Type Thermocouple Compensation Cable

KXS-FP3F Fluoroplastic Insulated Aluminum/Plastic Composite Tape, Shielded Fluoroplastic Sheathed Precision K Type Thermocouple Compensation Cable

KXS-FFP3 Fluoroplastic Insulated and Sheathed Aluminum/Plastic Composite Tape, Total Shielded Precision Class K Thermocouple Compensation Cable

KXS-FP3FP3 Fluoroplastic Insulated Aluminum/Plastic Composite Tape, Shielded and Overall Shielded Fluoroplastic Sheath Precision Class K Thermocouple Compensation Cable

Compensating Wire Type K ZR-KC-FVP-2*1.5 Thermocouple Sensor Temperature Measurement Extension Cable ;

Note: The above basic models only list copper wire or tin-plated wire shielding methods. Other shielding type models only need to change the shielding code, such as adding "ZR" before the model number for flame-retardant type P2, P3, adding "22" after the armored cable model number, ZR192 is an imported PFA material with a temperature resistance of 260°C.

询价单
主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  
 点击确定代表您同意《服务条款》《隐私政策》
 
 Click submit means you agree to《Service terms》《Privacy policy》

Phone Consultation

Consultation Phone:
15956082563

QQ Service

QQ Service:
1783827831

Back to Top