Compensating Wire ZA-KX-YVRP1 Thermocouple Compensating Cable Tin-Plated Shielded Temperature Measurement Wire_SupplyPro Co., Ltd._Anhui Maocheng Electrical Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》

Compensating Wire ZA-KX-YVRP1 Thermocouple Compensating Cable Tin-Plated Shielded Temperature Measurement Wire

产品Price 3.50/Rice

最小起订Quantity:1 Rice 供货总Quantity: 10000 Rice

用手机扫描二维码直达商品手机版
MobileView details
Location:
Anhui/Chuzhou
有效期至:
长期有效
最后更新:
2023-09-19 13:56
Product Details

Compensating Wire ZA-KX-YVRP1 Thermocouple Compensation Cable Tin-Plated Shielded Temperature Measurement Wire

Common compensation wires include the following types:

Compensation Conductor

Wire model

Fitted with heat

Electrode

Tolerance grade

Compensating Conductor Alloy Wire

Insulation layer

Colored

Allowable tolerance at 100℃

℃)

Allowable tolerance at 200°C

℃)





Positive electrode

Negative Pole

Positive electrode

Negative Pole

Standard Grade

Precision grade

Standard Grade

Precision grade



SC

S

SPC (Copper)

SNC (Copper-Nickel)

Red

Green

±5

±3

±5

-

KC

K

KPC (Lead)

KNC (Copper-Nickel)

Red

Blue

±2.5

±1.5

-

-

KX

K

KPX (Nickel Chrome)

KNX (Nickel Silicon)

Red

Black

±2.5

±1.5

±2.5

±1.5

EX

E

EPX (Nickel Chrome)

ENX (Copper-Nickel)

Red

Brown

±2.5

±1.5

±2.5

±1.5

JX

J

JPX (Iron)

JNX (Copper-Nickel)

Red

Purple

±2.5

±1.5

±2.5

±1.5

TX

T

TPX (Copper)

TNX (Tungsten-Nickel)

Red

White

±1.0

±0.5

±1.0

±0.5

 


The purpose of using compensating conductors:

(1) Move the reference end of the thermocouple from a high-temperature location to a more stable environmental temperature area.

(2) Saves a substantial amount of precious and rare metal materials used in the manufacturing of thermocouples.

(3) The use of compensating wires facilitates installation and laying of the lines.

(4) Replacing thermocouple wires with thicker diameters and higher conductivity can reduce the resistance in the thermocouple circuit, benefiting measurement and automatic control.

When using compensating conductors, please note the following points:

(1) Various compensation wires are only compatible with the corresponding thermocouple models. This means that the thermoelectric properties of each thermocouple and its matching compensation wire must be identical within the specified temperature range (0~100℃).

(2) The temperature at the compensation wire and thermocouple connection point must not exceed the specified operating temperature.

(3) When compensating wires and thermocouples are connected to instruments, the positive and negative poles must not be reversed, and the two pairs of connection points must be at the same temperature.

(4) Select the wire diameter of the compensating conductor based on the circuit resistance requirements of the instrument to be matched.

Compensating Wire ZA-KX-YVRP1 Thermocouple Compensation Cable Tin-Plated Shielded Temperature Measurement Wire

询价单
主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  
 点击确定代表您同意《服务条款》《隐私政策》
 
 Click submit means you agree to《Service terms》《Privacy policy》

Phone Consultation

Consultation Phone:
15956082563

QQ Service

QQ Service:
1783827831

Back to Top