产品Price 4.20/Rice
最小起订Quantity:1 Rice 供货总Quantity: 10000 Rice
Thermocouple Compensation Wire KX-FP2VP2, Shielded Temperature Measurement High-Temperature Extension Type Detailed Explanation of Thermocouple Compensation Wire, Structure and Definition: Thermocouple compensation wire, commonly referred to as compensation wire, is typically composed of alloy wire, insulation, sheath, and shielding layer. Within a certain temperature range (including room temperature), it consists of a pair of insulated wires with the same nominal electromotive force as the matched thermocouple. These wires are used to connect the thermocouple to the measuring device to compensate for the temperature variations at the connection point between them and the thermocouple, thus reducing errors. Two, using compensating cables between thermocouples and measuring devices offers two advantages: 1. Enhance the physical and mechanical properties of thermocouple temperature measurement lines. Utilizing multi-strand cores or small-diameter compensating wires can improve the flexibility of the lines, facilitate wiring, and also adjust the line resistance or shield external interference. 2. Reduce the cost of measuring lines; when the thermocouple is far from the measuring device, using compensation wires can save a significant amount of thermocouple material, especially when using precious metal thermocouples, where the economic benefits are even more pronounced. Section 3: Terms and Symbols: (1) Extended Compensation Wire: Also known as extended wire, the extended compensation wire has the same nominal chemical composition of the alloy wire and the nominal electromotive force as the thermocouple it is paired with. It is indicated by the letter "X" appended after the thermocouple type number, e.g., "KX" indicates an extended compensation wire for a K-type thermocouple. (2) Compensation Compensation Wire: Also known as compensation wire, the nominal chemical composition of its alloy wire is different from that of the thermocouple it is paired with. However, its electromotive force value is the same as the nominal value of the electromotive force of the paired thermocouple at 0-100℃ or 0-200℃. It is indicated by the letter "C" appended after the thermocouple type number, such as "KC". Different alloy wires can be applied to the same type number of thermocouples and distinguished by additional letters, such as "KCA", "KCB". Currently, it is not widely used. (3) Allowance: The allowance for thermocouple compensation wires is due to the large deviation caused by the compensation wire in the measurement system. This value is expressed in microvolts, and the size of the allowance is divided into precision grade and ordinary grade. (4) Symbols: S - indicates precision-grade thermocouple compensation wire. No letter is marked for general-grade compensation wire; G - indicates general-purpose compensation wire; H - indicates heat-resistant compensation wire; R - indicates compensation wire with multi-strand core. No letter is marked for compensation wire with a single-strand core; P - indicates compensation wire with a shielding layer; V - indicates insulation or sheath made of polyvinyl chloride (PVC); F - indicates insulation made of polytetrafluoroethylene; B - indicates sheath made of non-glass fiber material. KX-HA-FFRP Fluoroplastic烯 Insulated and sheathed copper wire braided overall shield precision grade K thermocouple compensation flexible cable KX-HA-FPFP Fluoroplastic Insulated and Sheathed Copper Wire Braid Screened Precision Class K Thermocouple Compensation Cable KX-HA-FPFRP Fluoroplastic insulated and sheathed copper wire braided screen, precision grade K thermocouple compensating soft cable KX-HA-FVP Fluoroplastic烯 Insulated Polyvinyl Chloride Sheath Copper Wire Braid Overall Shielding Precision Grade K Temperature Compensating Cable KX-HA-FVRP Fluoroplastic烯绝缘 Polyvinyl Chloride sheath copper wire braided overall shielding precision grade K thermocouple compensating flexible cable KX-HA-FPVP Fluoroplastic Insulated PVC Sheath Copper Wire Braid Screening Precision Class K Thermocouple Compensation Cable KX-HA-FPVRP Fluoroplastic Insulated PVC Sheathed Copper Wire Braid Screened Precision K Class Thermocouple Compensation Flexible Cable KX-HA-FGP Fluoroplastic烯 Insulated Silicon Rubber Sheath Copper Wire Braid Total Shield Precision Grade K Thermocouple Compensation Cable KX-HA-FGRP Fluoroplastic烯Insulating Silicone Rubber Sheath Copper Wire Braid Total Shield Precision Grade K Temperature Compensating Flexible Cable KX-HA-FPGP Fluoroplastic Insulated Silicone Rubber Sheath Copper Wire Braid Screened Precision K Type Thermocouple Compensation Cable KX-HA-FPGRP Fluoroplastic Insulated Silicone Rubber Sheath Copper Wire Braid Screened Precision Class K Thermocouple Compensation Flexible Cable KX-FP3F Fluoroplastic Insulating Aluminum/Plastic Composite Tape, Shielded Fluoroplastic Sheath General Grade K Type Thermocouple Compensation Cable KX-FP3FP3 Fluoroplastic Insulated Aluminum/Plastic Composite Tape, Shielded and Overall Shielded Fluoroplastic Sheath, Standard Grade K Type Thermocouple Compensation Cable KX-FFP3 Fluoroplastic Insulated Fluoroplastic Sheathed Copper Woven Aluminum/Plastic Composite Tape Overall Shielded General Grade K Type Thermocouple Compensation Cable KXS-FP3F Fluoroplastic Insulated Aluminum/Plastic Composite Tape, Shielded Fluoroplastic Sheathed Precision K Type Thermocouple Compensation Cable KXS-FFP3 Fluoroplastic Insulated and Sheathed Aluminum/Plastic Composite Tape, Total Shielded Precision Class K Thermocouple Compensation Cable KXS-FP3FP3 Fluoroplastic Insulated Aluminum/Plastic Composite Tape, Shielded and Overall Shielded Fluoroplastic Sheath, Precision Grade K Thermocouple Compensation Cable Thermocouple Compensating Wire KX-FP2VP2; Shielded Temperature Measurement High-Temperature Extended Type Note: The above basic models only list copper wire or tin-plated wire shielding methods. Other shielding type models only require changing the shielding code, such as adding "ZR" before the model for flame-retardant type P2, P3, adding "22" after the armored cable model, ZR192 is an imported PFA material, with a temperature resistance of 260°C.


Phone Consultation
QQ Service