Clean various heat exchangers, condensers, industrial pipelines, boilers, and steam power plant condensers. GlanChem partnership ensures reliability.
Jining Greentech Chemical Technology Co., Ltd. (Abbreviated to Jining Greentech)Green Clean CompanyEstablished2010Year,Is industrialA variety ofHeat Exchange EquipmentWashingNo translation provided.ProfessionalCompany. The company hasComplete SetOur business philosophy, industrial equipment cleaningTechnologyOur R&D capabilities, capable of handlingIndustrial, Private Enterprises,Industrial chemical equipment, power plant equipment, power plant condenser, boiler, and boiler air preheater cleaning servicesAir conditioning cleaning, heat exchange equipment cleaning, handling cleaning for machinery and equipment, chemical equipment, etc.; undertaking cleaning and descaling for refrigeration and heating equipment.
Cooling Tower Cleaning, Evaporative Condenser Filling Material Replacement Service, Yicheng, Zaozhuang, Shandong

JiningGreens Cleaning Company stocks250mpa数十 models of cleaning machines, over a dozen chemical cleaning pump stations. Mainly serving enterprises: power plants, chemical factories, oil refineries, food factories, public institutions, heating equipment, etc., the company also provides long-term services forIndustryCustomers perform cleaning and design of industrial heat exchangers.
Our company has newly acquired domestic cleaning machines and imported cleaning equipment. We have hired experienced professionals in the cleaning industry.Technical SpecialistStandardization and regularization achieved in heat exchange equipment cleaning。
Cooling Tower Cleaning, Evaporative Condenser Filler Replacement Service in Yicheng, Zaozhuang, Shandong

Chemical Cleaning Scale Removal Process
Recirculating cleaning utilizes two original parallel ash removal pipelines to form a loop, creating a recirculation system with the cleaning pump station. A solution of a certain acidity concentration is added, and the ash water flows in a recirculation pattern for cleaning within the pipeline. As the acid cleaning reaches a certain level, the solution is continuously replenished. For short-distance single ash water pipelines, if conditions permit, a temporary pipeline can be laid to form a recirculation loop for cleaning. This process must be carried out while the system is offline, and it is complex and costly.
No two ash pipes can form a loop during cleaning; only single-pipe open circuit cleaning is allowed. The method involves connecting one end of the ash pipe to the cleaning unit, continuously preparing a specific concentration of cleaning solution in the liquid tank, and then continuously or intermittently injecting it into the ash pipe. This process requires adding cleaning equipment while the system is offline, which increases costs.
Cooling Tower Cleaning, Evaporative Condenser Filler Replacement Service - Yicheng, Zaozhuang, Shandong

This process involves continuously injecting a specific quantity of acidic fluid while operating the ash delivery pipes, simultaneously introducing a certain amount of ash delivery pipe cleaning inhibitor and pipeline cleaning descaler for open-circuit cleaning. The primary function of the cleaning aids is to promote the reaction between the acidic fluid and ash deposits in a solution at a certain concentration and flow rate, while also increasing its solubility in water and reducing the formation of gas blockages, ensuring the quality of ash pipe cleaning.
Cooling Tower Cleaning, Evaporative Condenser Filling Material Replacement Service in Yicheng, Zaozhuang, Shandong

High-pressure water jet cleaning offers advantages such as high efficiency, low cost, non-damaging to workpieces, environmental protection, ease of operation, and safety.
High-pressure water technology boasts the following advantages.
Since the pressure of high-pressure water is less than the compressive strength grade of metal, high-pressure cleaning will not damage the base material being cleaned.
Cooling Tower Cleaning, Evaporative Condenser Filling Material Replacement Service - Yicheng, Zaozhuang, Shandong

Components cleaned with high-pressure water jetting do not require secondary cleaning; however, after chemical cleaning, the surface must be rinsed with clean water.
(1) Classified by chemical composition, they can be categorized into carbonate scale, sulfate scale, silicate scale, and mixed scale. The main components of carbonate scale are calcium carbonate and magnesium carbonate; the main components of sulfate scale and silicate scale are calcium sulfate and silicate compounds, respectively.
Lime scale primarily forms due to the salts of calcium and magnesium present in the boiler feed water, which precipitate and adhere to the metal surface upon heating. The thermal conductivity of lime scaleCorrosion intensifies, causing pipeline scale corrosion and accelerating the damage to the heated surfaces. Scale formation should be promptly removed using either mechanical or chemical methods.
Heat Exchanger & Refrigeration Equipment Cleaning - Choose GreenChem for Reliability