    Rainwater AbsorptionIt is a widely-used drainage method for high-rise buildings currently.Siphon Rain GutterThe entire system is composed of oil pipelines. We've discussed the technology and principles of pipeline installation extensively. Now, we're talking about the stability of the pipeline.
The junction between the siphon rain head and the drainage pipe is a common problem area and must be paid close attention to during installation.Rainwater HarvestingThe stability of the pipeline will determine the overall system's stability and drainage capability. When a siphon is formed in the pipeline, the internal pressure is high, and poor connections can lead to air intake, affecting drainage efficiency. Unstable drainage pipelines may also cause cracking and air intake phenomena.
How to reinforce pipelines and maintain their stability? We need to pay attention to strengthening several steps during construction. Firstly, place a section of steel sleeve in the floor hole and seal the gap between the mortar steel pipe and the floor tightly, leavingSiphon Rain HeadHoles were installed, and the area within 1m of the rain tray was leveled with mortar. After the mortar had cured and dried, the steel sleeve was removed. Then, a 2mm waterproofing material was applied to the leveling surface to prevent air bubbles. Next, the assembled siphon rain tray was inserted into the reserved position, aligning the center of the rain tray with the center of the reserved hole. The assembly was then firmly pressed into place.A虹吸Rain Harvesting BasinInstall a sheet, causing the surrounding coating to buckle. Finally, secure the downspout with collision cement nails to the concrete floor slab, filling the gap between the downspout and the reserved hole with cotton, asbestos, and cement.