Armored Multicore Communication Cable HYAP22-30X2X0.5_供应产品_Tianjin Cable Corporation, First Branch 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》

Product Center

Company Qualification

Tianjin Cable Corporation, First Branch

Business Model:
Location: Guangdong
Contact person:毕润乐 (先生)
Mobile号码:13833441274
Company Address:Biyanma Industrial Zone

Armored Multicore Communication Cable HYAP22-30X2X0.5

供应产品
  • Armored Multicore Communication Cable HYAP22-30X2X0.5

    Hotline:13833441274

    Details Introduction

    Armored High-Density Communication Cable HYAP22-30×2×0.5 Technical Analysis
    I. Model Definition and Structure
    HYAP22‌:
    H: Intra-city Communication Cables (for Fixed Installation)
    Solid polyolefin insulation (high stability in high-frequency signal transmission)
    Aluminum-plastic composite tape with moisture-proof layer (dual protection against moisture and corrosion)
    Copper wire braided shield layer (coverage ≥, anti-electromagnetic interference)
    22: Double steel belt armored + polyethylene outer sheath (compressive strength ≥ 50 kN/m²).
    30×2×0.5‌:
    30 pairs: Twisted pair count (supports parallel transmission of multiple signals).
    2×0.5: Each set contains 2 conductors (single conductor cross-sectional area 0.5mm², copper core diameter approx. 0.8mm).
    II. Key Performance Parameters
    Parameters Technical Specifications Standard Basis
    Conductor Resistance ≤95Ω/km(20℃) GB/T 3956‌
    Insulation voltage resistance No breakdown at 1kV/min (thickness ≥ 0.4mm) GB/T 7594.2‌
    Shielding Effectiveness ≥60dB(100kHz-1GHz) MT 386‌
    Operating Temperature -40°C to 70°C GB/T 13849‌
    Bend Radius ≥8 times the outer diameter (dynamic laying) YD/T 1019-2013‌
    Section 3: Application Scenarios
    Mine Communication System: Suitable for explosion-proof and monitoring signal transmission in coal mine shafts (must comply with MT 386 flame-retardant standard).
    Industrial Control Networks: Supports RS485/CAN protocols for data interaction between PLCs and devices.
    Long-distance Transmission: Direct burial installation with IP67 protection level, resistant to mechanical damage.
    Section 4: Certification and Laying Requirements
    Mandatory Certification: Coal Safety Certification (MA Mark), MT 386 Flame Retardant Certification
    Laying Standards: Direct burial depth ≥ 1.2m,牵引 tension ≤ 80% short-term tensile strength (≤1500N).

    Tianjin Cable Corporation, First Branch

    Inquiry Message
     Click submit means you agree to《Service terms》《Privacy policy》
    Contact us
    • 毕润乐 (Mr.)

    • 13833441274

    • 13833441274

    • 1301702141@qq.com

    • Biyanma Industrial Zone

    b2b.china9.net © Zhongshang 114 Hebei Network Technology Co., Ltd.Address: Room 6009, Oriental New World Center, No.118 East Zhongshan Road, Qiaoxi District, Shijiazhuang City, Hebei ProvincePlatform Service Hotline: 4006299930

     Click submit means you agree to《Service terms》《Privacy policy》