E010 Press the pause switch, then reset using the control panel's RESET button.
E011 Press the pause button. Press the RESET key to clear the fault. Press the key to move the fabric for seam joining.
E015 Press and hold the pause button continuously, or there is poor contact with the pause button. Turn off the power to confirm the insertion status of the main circuit board plug P13.
E016 Poor switch contact, confirm the insertion status of the main circuit board connector P13 by turning off the power.
The above lists common fault codes for the emergency stop switch of the Brother G model pattern machine. E010 and E011 are normal prompts after operating the stop switch and can be resolved. E015 and E016 typically indicate a damaged emergency stop switch, with a few cases being a damaged mainboard.
E025 E035 Typically, the pedal switch is pressed when the device is turned on. If the pedal switch plug is pulled out and no error code is reported, it is determined that the pedal switch is faulty; otherwise, the mainboard is damaged.
E036 Incorrect pedal type setting; please correctly set the options in switch 050 or 003.
E050 E055 Check the head inverted switch during startup.
E051 Operating while checking the inverted switch on the head.
E065 Error: Detected a pressed button on the operational panel at startup, typically indicating a faulty panel button.