The E200 is unable to detect the origin of the X-axis fabric feeding motor. There is an abnormality with the X-axis fabric feeding motor or the X-axis origin sensor is poorly connected. Please turn off the power and check the insertion status of the PMD circuit board plug P10 and the main circuit board plug P20.
E201 The X-axis fabric feeding motor has stopped abnormally. Please turn off the power and check for any anomalies in the X-axis fabric feeding direction. Please confirm if fuse F2 has blown.
The origin adjustment data for the E202 X-axis or Y-axis cloth feeding motor is abnormal. Please perform the origin adjustment again.
The E210 cannot detect the origin of the Y-axis fabric feeding motor. There is an abnormality with the Y-axis fabric feeding motor or the Y-axis origin sensor is not properly connected. Please turn off the power to confirm the insertion status of the PMD circuit board's plug P8 and the main circuit board's plug P4.
E211 Error: Y-axis fabric feeding motor has abnormally stopped. Please turn off the power to check for any anomalies in the Y-axis fabric feeding direction. Confirm if fuse F2 has blown.
To determine whether the issue is with the PMD circuit board, mechanical components, motor, or sensor, the machine's input/output detection function can be utilized. For assistance, please contact Dongguan Sanyou Automation Technology Co., Ltd.