The long-term allowable working temperature for the conductors of insulated and sheathed control cables should not exceed 70°C. During installation, the cable temperature should be at least 0°C, and the bending radius should be at least ten times the cable's outer diameter. For cables with armor or copper tape shielding, the bending radius should be at least twelve times the cable's outer diameter.
Characteristics of cables with insulation and sheath control for assembly:
The long-term allowable working temperature for the cable conductor is 70°C.
2. The laying temperature of the cable should not be below 0°C. The recommended allowable bending radius: For cables without armor layer, it should be no less than 6 times the outer diameter of the cable. For cables with armor or copper tape shielding, it should be no less than 12 times the outer diameter of the cable. For flexible cables with shielding layer structure, it should be no less than 6 times the outer diameter of the cable.
Application Scope
Model | Name | Application Scope |
KVV | Poly-insulated, poly-jacketed control cable | Installed indoors, in cable trenches,管道 interiors, and underground. |
KVVP | Composite insulated, jacketed copper wire braid shielded control cable | Installed indoors, in cable trenches, pipelines, and underground, with anti-interference capability |
KVVP | Poly-insulated, poly-jacketed soft control cable | Installed in indoor environments requiring flexibility and softness. |
KVVRP | Assembled insulated, sheathed copper wire braided shielded soft control cable | Same as above with anti-interference capability. |
KVVP2 | PVC insulated, sheathed copper tape wrapped shielded control cable | As above. |
KVV22 | Assembled insulated, steel tape armored control wire with sheath | Installed indoors, in cable trenches, pipes, and underground, capable of withstanding significant mechanical external forces. |
KVV32 | Assembled Insulation, Fine Steel Wire Armored Polyethylene Sheathed Control Cable | Installed indoors, in cable trenches, pipelines, shafts, and underground, it can withstand certain tensile forces. |
Note: Flame-retardant (ZR) and halogen-free flame-retardant (ZRA) control cables can be produced according to customer requirements.
Production Range
Model | Rated Voltage (V) | Conductor Nominal Section Area (mm²) | |||||
0.5 | 0.75 | 1.0 | 1.5 | 2.5 | 4 | 6 | 10 |
Core Count | |||||||
KVV KVVP | 450/750 | - | 2-61 | 2-14 | 2-10 | ||
KVVP2 | - | 4-61 | 4-14 | 4-10 | |||
KVV22 | - | 7-61 | 4-61 | 4-14 | 4-10 | ||
KVV32 | - | 19-61 | 7-61 | 4-14 | 4-10 | ||
KVVR | 4-46 | - | - | ||||
KVVRP | 4-61 | 4-48 | 4-4 |