Metal Shielded Power Cable_SupplyPro Co., Ltd._Anhui Global Communication Instrument Cable Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Anhui Global Communication Instrument Cable Co., Ltd.

Cable Wires, Instruments and Meters, Communication Cables and Accessories

Consultation Hotline
0550-7512577  13965982658

Product Categories
Home > SupplyPro Co., Ltd. > Metal Shielded Power Cable
Metal Shielded Power Cable
品牌: Global Communication Instrument Cable
Production Execution Standards: Array
Metal Shielding: Metal wire braiding or metal strip wrapping
Highest Operating Temperature: Polyvinyl chloride insulation is 70°C; cross-linked polyethylene insulation is 9°C.
单价: 电议
最小起订Quantity: 100 Rice
供货总Quantity: 100000 Rice
有效期至: 长期有效
最后更新: 2023-04-01 13:43
 
详细Info

This product is suitable for power lines rated at 0.6/UV and below for transmitting electrical energy. It boasts strong electromagnetic interference resistance, lightning strike protection, and balanced potential, making it particularly ideal for sensitive electronic facilities such as computer centers, aerospace monitoring centers, and intelligent buildings.

— Production Execution Standard GB/T12706-1-2002

Model Name

Model Name: 垮

Copper  Aluminum

VVP

VVP22      VLVP

VLVP22 Copper and Aluminum Core Polyvinyl Chloride Insulated Metal Shielded (Steel Tape Armored) Polyvinyl Chloride Sheathed Power Cable

YJVP

YJVP22     YJLVP

YJLVP22 Copper-aluminum core cross-linked polyethylene insulated metal sheathed (steel tape armored) polyvinyl chloride jacket power cable

Note: 1. This product can be designed with flame-retardant properties to meet the user's requirements. Simply add "ZR--" before the original model number when placing an order.

NH--Indicates refractory type:

2. The metallic shielding of the cable can be made in two forms as per customer request: wire braid or metallic tape wrap.

3. For cables with a soft-core conductor, add the letter "R" after the original model number.

III. Specifications

Model           Core Count           Nominal Section Area

Copper Aluminum

VVP

YJVP          VLVP

YJLVP        1 4〜300

VVP                    VLVP         2       4〜185

VV22P                         VLV22P    3      

YJVP                            YJLVP        3+1  1

YJV22P                        YJLV22P   4 4-185


IV. Terms of Use

1. High conductor long-term allowable operating temperature: Polyvinyl Chloride insulation at 70°C; Cross-linked Polyethylene insulation at 90°C.

2. In case of cable short circuit (duration not exceeding 5 seconds), the conductor's temperature shall not exceed: 16°C for polyvinyl chloride insulation : 25°C for cross-linked polyethylene insulation.

3. The installation environment temperature should not be below 0°C.

4. The cable bend radius allowance is as follows: armored cable not less than 20 times the cable outer diameter; unarmored cable not less than 15 times the cable outer diameter; soft-core conductor cable not less than 10 times the cable outer diameter.

V. Approximate Outer Diameter of Cable

The outer diameter of VVP and VLVP cables is increased by 1 to 1.5mm compared to that of VV and VLV cables.

The outer diameter of VJVP type cables is 1~1.5mm larger than that of YJV type and Y/V type cables.

VV22P and VLV22P cables have an outer diameter increased by 1 to 1.5mm compared to the VV22 and VLV22 cable types.

The VJV22P and YV22P cable outer diameters are increased by 1 ~ 1.5mm respectively, based on the outer diameters of the YJV22 and Y-ILV22 cable types.

Section 6: Main Technical Parameters

1、20Refer to the DC resistance of the conductor at C for 0.6/1 kV polyvinyl chloride insulated and sheathed power cables.

Insulating Resistance

Serial Number   Performance   Polyvinyl Chloride Insulation   Cross-linked Polyethylene Insulation

Volume resistivity (at 20°C, when the cable is in operation) 1013

10|0

Insulation Resistance Constant (20°C) - Cable Operating Temperature: 36.7

0.037        3.67

3. The finished cables undergo AC voltage test with an AC voltage of 3.5kV at 50Hz for 5 minutes, and the insulation should not be pierced.

4. The fire-resistant cable should meet the fire-resistant requirements of Class A or B tests as specified in IEC60331 or GB12666.6.

5. Flame-retardant cables shall meet the flame-retardant performance requirements of either Category A, B, or C as specified in IEC60332 or GB/T18380.3 standards.

Section 7: Delivery Length

1. Per the agreement between both parties, delivery of cables of any length is permitted. 2. Length measurement error is not to exceed ±0.5%.

询价单
 Click submit means you agree to《Service terms》《Privacy policy》

13965982658