Publish Time:2019-09-24        View Count:337        Return to List

18kw Shenzhen Diesel Generator

Silent Diesel Generator Set18kwThe lifespan of diesel generators is directly related to factors such as the environment of the machine room, inadequate daily maintenance, and the replacement of equipment components. Extended idling or low-speed operation of diesel generators can lead to the buildup of carbon deposits, which reduce the engine's output power, affecting the overall power output of the generator set, and even creating a false impression of normal operation. Once subjected to actual load, major malfunctions in the diesel generator set may occur. The formation of carbon deposits: Due to excessively low combustion chamber temperatures, fuel cannot be completely combusted, causing carbon buildup that blocks the nozzle holes and piston rings, and results in "black oil" overflowing from the exhaust pipe. Some unburned diesel washes away the lubricating oil on the cylinder walls and dilutes the engine oil in the crankcase, harming all running parts in the engine due to poor lubrication. Therefore, we should also pay attention to various abnormal symptoms of the generator set during normal use.

 Type    ID:      TO20000ETX

No content provided for translation.:Generator specifications:

1.Rated Power:18KW

2.StandbyPower:      19KW

3.Rated Frequency:50HZ

4.Rated Voltage:220/380V

5.Power Start

6.Institution Type: Silent

7.Power Factor:0.8/1.0

8.Volume: Single/Three-phase

9.Rare Earth Permanent Magnet Motor

 

No content provided for translation..Engine Specifications:

 

1.Engine Brand:Small Quiet

2.Engine Model:TO-WP18

3.Cooling Method: Water Cooling

4.Rated Speed:1500r/min

5.Cylinder Structure: Direct Injection, Four-Cylinder, Inline, Water-Cooled

6.Direct Injection Combustion System

7.Inlet Method: Natural Aspiration

8.Insulation Grade:HLevel

9.Control Device:ECU

10.Silencer Device: IndustrialNoise Suppressor

11.Speed Regulation Method: Mechanical Speed Regulation

12.Fuel Tank Capacity:50L

13.Overload Capacity:100%

14Compression Ratio:19:1

15Crankshaft Special: Counterclockwise

 

No Chinese content provided.:Complete Machine Parameters:

1.Fuel Gauge:     Present

2.Voltage Meter: Available

3.Output Indicator: On

4.Overload Protection: N/A

5.Oil Control Device: Available

6.Machine Fuel Consumption:200g/kw.h(loaded)

7.Office Hours:9-14H

8.Noise Level:62-72db

9.Machine Weight:490/590kg

10.No Chinese content provided.:      1450*870*1000(Without Wheels)

11.After-sales Service: Daize Original, Nation-wide Warranty

 

Four.Random Accessories:

1.Manual, warranty card, certification of conformity, connection cables, random small tools, tool kit

 


There are numerous methods to diagnose generator set malfunctions, with the most commonly used being the isolation method, comparison method, verification method, and instrument inspection method.

1The method of isolation involves stopping the operation of an individual cylinder or sequentially stopping several, even all, cylinders from injecting fuel, observing the machine's performance before and after the fuel injection is halted. This method is effective for inspecting the working condition of each cylinder, particularly for checking the color of the exhaust smoke from each cylinder.

2Comparison Method

Comparative methods are commonly used. After a generator set malfunctions, if there is suspicion about a particular component or system, replace it with a high-quality part or a normal system and observe if the fault is eliminated. If the fault disappears, it proves that the fault occurred in that component or system.

3Verification Method

The verification method involves tentative adjustments or disassemblies based on known causes of failure, to check the accuracy of past analyses, thereby identifying the source of the fault.