详情描述

Part 1: System Composition Overview

The system is composed of the following components:

The function of the test chamber is to provide a stable environment with constant high and low temperature and humidity, as well as alternating high and low temperature and humidity; it includes a refrigeration system, heating system, humidification/dehumidification/waterway system, air duct system, control system, and system safety protection devices.

Part 2Main Technical Specifications of the Test Box

1. Studio size: 1000×1000×1000mm (width x depth x height)

2. Dimensions approximately: 1510×1560×1860mm (width×depth×height)

3. Temperature range: -40°C to +150°C

4. Temperature fluctuation: ≤±0.5℃

5. Temperature uniformity: ≤±1℃

6. Temperature Deviation: ≤±2℃

7. Rate of temperature rise/fall

From +20°C to -40°C, approximately 60 minutes

From +20 to 100°C, approximately 40 minutes

8. Humidity Range: 20% - 98% R.H. (AT +25℃ to +85℃)

9. Humidity Error: +2/-3% R.H. (above 75% R.H.), ±5% R.H. (below 75% R.H.)

10. Wind Speed: 1.7 ~ 2.5 m/s

These metrics were obtained under conditions of an ambient temperature ≤25°C, atmospheric pressure, and with the container unloaded and unburdened, within a 1/6th space from the inner wall of the container.

11. Power: approximately 12.5 kW

12. Power: 380V ± 10%V; 50Hz

Comply with relevant standards and testing methods:

GB/T2423.22-87Nb     GJB1032-90         MIL-STD-2164/(E/C)

GB/T2423.4-93        GB/T2423.34-86        GJB150.9-86

Section 3: Key Components Selection for Test Box