NS-4 Comprehensive Protector Wiring Diagram_SupplyPro Co., Ltd._Du'an Environmental Protection Equipment (Jiangsu) Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Du'an Environmental Protection Equipment (Jiangsu) Co., Ltd.

Environmental equipment, pumps, water treatment systems, mechanical accessori...

Consultation Hotline
025-57523831   13813381829

Product Categories

Contact Information
  • Contact person:李经理
  • Telephone:025-57523831
  • 邮件:63572853@qq.com
  • 传真:025-57523831
Home > SupplyPro Co., Ltd. > NS-4 Comprehensive Protector Wiring Diagram
NS-4 Comprehensive Protector Wiring Diagram
品牌: Du'an
Voltage:
Current: 5A
Weight: 1 lb
单价: 567.00/Only
最小起订Quantity: 1 Only
供货总Quantity: 1000 Only
有效期至: 长期有效
最后更新: 2024-11-19 10:31
 
详细Info

NS-4 Comprehensive Protection Relay Wiring Diagram

NS-4 AV220V 5A Submersible Pump Comprehensive Monitoring and Protection Device

     Ambient temperature surrounding does not exceed+40Degree,24Average temperature within the hour does not exceed+35DegreePlease provide the Chinese content that you would like translated into American English.Low environmental temperature must not be below-10Degree. 

      No excessive dust, acids, salts, corrosive gases, or relative humidity exceedingPlease provide the Chinese content to be translated.High temperature+40Within time limit50%At lower temperatures, higher relative humidity is permissible.  
   For instance:20Temperature below degrees, humidity is90%Be cautious of condensation that may occur accidentally due to temperature changes. 

    Altitude at installation site does not exceed1000Grain. 

     Vertical installation tilt must not exceed5Degree.

    During the operation of the submersible pump,In cases of water leakage in the pump oil chamber due to mechanical seal wear and other reasons,Controller through the pump onP31# P32#Signal line for monitoring, WhenP31#WithP32#An intermittent monitoring has detected water leakage exceeding the threshold.,Controller oil chamber leakage protection relay activates, oil chamber leakageLEDLight (red) blinking. Oil chamber leakage relay*High capacity2A 250VACAction state: closed.

   2.2 Water pump motor winding over-temperature protection

    During the operation of the submersible pump,In the event of an overheating fault in the pump motor winding due to overloading or other reasons (with the action temperature value being)135Degree,Controller through the pump onP11#P12#Or21#22#Signal line monitors it,WhenP11#Please provide the Chinese content to be translated into American English.P12#Intermittently monitored temperatures exceeding135Duty Time,Relay activated for over-temperature protection of the controller winding due to excessive heatingLEDLED (Red) blinking. Overheating relay coilFewerHigh capacity2A 250VACAction status: closed.

   2.3 Water Pump Motor Cavity Water Immersion Protection

   When a submersible pump is damaged due to reasons such as seal wear,Pump motor cavity water immersion fault occurs,Controller via pumpP51# P32#Signal line for monitoring,WhenP51#WithP32#Intermittently detected water leakage exceeding the limit,Control module motor fault protection relay activated, motor submerged in waterLEDLED (red) blinking. Fault relay.*High capacity1A 250VACTwo independent outputs (normally open, normally closed). 

2.4 Water Pump Terminal Box Ingress Protection against Water Immersion
    When the submersible pump is due to seal wear and other reasons,Pump junction box cavity experiencing water immersion fault,Controller through the pumpP41# P32#Signal line for monitoring,WhenP41#WithP32#Intervening monitoring detects water leakage exceeding the limit.,Control panel wiring box cavity submersible water-protected relay activation, wiring box submergedLEDFlashing light (red). Line box water immersion relay*High capacity2A 250VACAction state: closed.

2.5 Protective device for overheated pump bearings
    When the pump shaft bearing of a submersible pump overheats due to reasons such as overloading (with the operating temperature value of)105Degree,Controller through the pump onP61# P32#Signal line for monitoring,WhenP61#Please provide the Chinese content to be translated into American English.P32#Intermittently monitored temperatures exceeding105Degree timing,Control module motor fault protective relay activated, bearing overheatingLEDLight indicator (red) flashing. Fault relay.*High capacity1A 250VACTwo independent outputs (normally open, normally closed).

Warranty Period: One year - the seller is responsible for free repairs or replacements within one year in case of any issues!

 

NS-4 Comprehensive Protection and Monitoring Controller Features
Input Voltage: AC220V, 50Hz, rated power consumption less than 10W.
Ambient Temperature: -20℃~75℃。
Ambient Humidity: Less than 90% (no dew condensation).
SensorPower Supply: SensorDC12V low-voltage power supply
         Power supply transformerApplianceIsolation
Signal Input: Input Hysteresis Control: ±2%
Signal Input: DC12V switch signal input or resistance/current signal input.
Signal Response Speed: 10 mS.
Signal Output: Relay output, Contact Rating: 5A/250VAC or 5A/30VDC.
NS-4 Comprehensive Monitoring Controller Model
Signal Input: Winding Sensors: Winding Overheat Protection
       Leakage Sensor: Oil chamber water immersion protection
Wiring boxSensor: Wire box water immersion protection.
       Overload Signal: Overload Protection
MotorCavity Sensing: Motor Water Immersion Protection
       Pump Operation Signal: Pump Operation Monitoring
       Moisture Sensor: Dehumidification heating, motor insulation prevention and dehumidification heating.

The Jiangsu Du'an Environmental Protection NS-4 type submersible pump integrated monitoring controller is well-crafted, including a communication management chip. This chip is connected to the microcontroller and communicates with the computer terminal, transmitting transformer temperature information to the computer terminal. Preferably, a buzzer is also connected to the microcontroller, which is linked to the circuit of the temperature probe. When the temperature probe makes poor contact, the buzzer emits an alarm. Preferably, the display unit includes a digital tube, a digital tube driver circuit unit, and a key input control unit, as well as a key signal input editing unit. The digital tube is connected to the digital tube driver circuit unit and the key input control unit, the key signal input editing unit is connected to the digital tube driver circuit unit and the key input control unit, and the digital tube driver circuit unit and the key input control unit are connected to the microcontroller.


询价单
主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  
 点击确定代表您同意《服务条款》《隐私政策》
 
 Click submit means you agree to《Service terms》《Privacy policy》

025-57523831