Wire Strong Traction Grating Machine
Portable格栅污物清除机
Membrane grille cleaning machine

Wire Rope Traction格栅Cleaning Machine Technical Parameters:
Parameter dimensions | GSHZ-300 | GSHZ-500 | GSHZ-800 | GSHZ-1000 | GSHZ-1200 |
Installation Angle | 60°~75° | 60°~75° | 60°~75° | 60°~75° | 60°~75° |
Rake tooth pitch(mm) | 100 | 100 | 100 | 100 | 100 |
Motor Power(kv) | 0.75 | 0.75 | 1.1 | 1.5 | 2.2 |
Flow Rate Through Water(T/h) | 405 | 1125 | 3600 | 4500 | 6300 |
Liquid Flow(m/s) | > 0.3 | > 0.5 | > 1 | > 1 | > 1 |
Effective Widthk1(mm) | 300 | 500 | 800 | 1000 | 12000 |
Basin widthk3(mm) | 550 | 750 | 1050 | 1250 | 1450 |
Overall Width of Equipmentk4(mm) | 880 | 1080 | 1380 | 1580 | 1780 |
Sink depthH(mm) | 1000~8000 | 1000~8000 | 1000~8000 | 1000~8000 | 1000~8000 |
Design, manufacturing, and factory testing technical requirements for wire rope tensioned格栅decontamination machines.
Standardized appearance, operation, maintenance, spare parts, and manufacturer's services; the equipment provided mustMeets on-site operational requirements.
Equipment List
An Assembled Please provide the Chinese content you would like translated into American English. Place | Regulation Grid | Grille style | Quantity | Note |
Rough grating and pump house for intake | B=800mm b=20mm H=7600mm α=800 | Revolving | 2 |
Supply Range
Jiangsu Du'an Environmental ProtectionThe provided wire rope traction mechanical coarse grate shall be a complete set, mainly including:(But not limited to): Rack, lattices and supports, enclosed turntable traction chains, driving units, differential mechanisms, unloading devices, cleaning and debris removal equipment maintenance and protection platforms, on-site electrical control cabinets, and fasteners, etc. The goods should not require additional parts during installation and safe, reliable operation.
Jiangsu Du'an Environmental Protection Grating AccessoriesDocumentation Submission:
Du'an Environmental ProtectionSubmit the following documents, but not limited to the following:
Detailed drawings and specifications of the equipment, indicating all installation dimensions and materials.
—Detailed performance specifications of the equipment;
—Installation, maintenance, and operation manuals;
—Manufacturing and Quality Assurance Facilities
—Detailed description of the installation method and installation accuracy specifications;
—Pre-commissioning debugging and testing requirements;
— Wiring diagram and control principle diagram for the grille control box;
—Weight of each part of the equipment.