Duwan 65-200A horizontal centrifugal pump price, single-stage horizontal pipeline centrifugal pump
Duwan 65-200A Single Stage Horizontal Centrifugal Pump, with Installation and Commissioning Included
Flow Rate: 23.5 cubic meters
Head pressure: 44 meters
Motor Power: 7.5 kW
Cast Iron
380V voltage

Jiangsu Du'an 65-200AThe single-stage horizontal end-suction pump features a rear-hinged door design. The shaft end seal requires a packaged mechanical seal. The primary seal (dynamic and static rings) should be made of high-strength, high-wear-resistant materials. The material, structure, and cooling flushing scheme of the mechanical seal should be reasonable and reliable.
Bearings are standard type rolling bearings, usingNSKOrSKFBrandBasic rating life of roller bearingsNot less than the normal service lifeUnder rated conditions, operate continuously for at least25000 HourPlease provide the Chinese content that needs to be translated into American English.At rated speed under both radial and axial loads, at least16000 Hour(s).
Pump and drive motor transmission connections should be made using a coupling for direct connection, couplingHarvestUtilize couplings with extended hub membranes. The pump shaft must possess adequate strength and rigidity to transmit the rated power of the prime mover; the surface roughness of the shaft and sleeve at the mechanical seal should not exceed0.8mThe shaft deflection must not exceed during operation within the allowable range of the pump.50m。
A replaceable and sturdy locking ring that won't rotate, made of wear-resistant material, should be placed between the impeller and the pump housing to maintain the pump's operation.HighEfficient operation.PumpMechanical seals are used, with the leakage of the mechanical seal not exceeding5mL/h。
WDSSingle-stage horizontal centrifugePump body and cover, including the shaft seal box and sealing end cover, must not exceed the nominal pressure of the pump flange. The pump body, including the shaft seal box and sealing end cover, features sufficient wall thickness for adequate structural integrity.NormalOperating TemperatureOperation.
Pressure gauge fittings should be installed at both the inlet and outlet of the pump body. A vent valve connection should be left at a higher point on the water pump outlet. Liquid drain connections should be set at the lower part or several low points of the pump, and sealed with a bolt plug.
The impeller is made of a single casting, ensuring its structural design guarantees the high-efficiency pumping of flushing water. ImpellerAvailableRigid fixation to prevent circumferential and axial movement during rotation in the specified direction.
A replaceable and sturdy locking ring that won't rotate, made of wear-resistant material, is installed between the impeller and the pump housing to maintain the pump's operation.HighEfficiency in operation.WDSHorizontal CentrifugalThe shaft of the pump has sufficient strength and rigidity to transmit the rated power of the prime mover; the roughness of the shaft and sleeve surfaces at the mechanical seal should not exceed0.8m.Pumps operate within their allowable working range with shaft deflection.GenerallyNo more than50m。
If equipped with a sleeve, it should be securely fastened to prevent movement of the sleeve along the circumference and in the axial direction. The sleeve should be tightly adjacent to the impeller hub to maintain a seal and prevent the shaft from becoming wet. Additionally, it should be ensured that the leakage between the shaft and sleeve does not confuse with the leakage passing through the mechanical seal face.
To prevent loss and contamination, the design of the bearing housing must not use gaskets and threaded joints to isolate the lubricant from the cooling fluid. All openings in the bearing housing should be designed to prevent the entry of debris and leakage under normal operating conditions.
WDSHorizontal CentrifugalThe pump is connected to the driving shaft with an elastic coupling, which is of a size to accommodate the higher torque requirements of the predetermined driving motor. The maximum rotational speed of the coupling matches all possible operating speeds of the pump's driving motor. A protective cover is fitted to the coupling.
The base should be a common base for both the pump and motor, with a design that allows for vertical adjustment of the driving unit to compensate for the tolerances between the pump driving unit and the base.
At any operating point on the pump characteristic curve, the motor's rated output shaft power should be at least greater than the pump shaft power by15%The motor must be designed for continuous operation and must meet a minimum of... per hour.10No startup requirements that would cause any harmful effects. The motor is equipped with overheat and overcurrent protection devices.

WDSSingle-stage centrifugal pipelinePump main materials:
Pump housing:Cast IronOr equivalent
Impeller:Cast IronOr equivalent
Spindle:Cast IronOr equivalent
Wear-resistant lining:Cast IronOr equivalent
Shaft Seal: Mechanical Seal
Du'an Environmental Protection WDSHorizontal CentrifugalPump factory-suppliedMaterials:
Equipment Origin, Country of Manufacture, and Full Name of Manufacturer
Form, model, specifications, physical dimensions, technical performance, and relevant parameters of the equipment
Basic bolt layout detail and civil load
Overall layout diagram of pump assembly
Pump assembly structure drawing
Detailed technical specifications
Part Material and Protective Coating Description
Dimensions and space requirements for the equipment's appearance, installation, and maintenance operation.
Electrical schematic and terminal wiring diagramØ Control Schematic
Manual or Equipment List
Centrifugal Pump Technical Data Sheet
Supply List (including Name, Quantity, Specifications, Performance Parameters, Material, Origin)
Installation, operation, and maintenance manual for equipment (provided after contract signing)

Duwan WDSHorizontal Single StageThe centrifugal pump supply range includes complete sets. A complete set consists of: centrifugal pump and its driving motor; common base and foot bolts, nuts, and washers; coupling.(Or)Spark-proof guard; mechanical seal; cooling water/Insulating hot water mixing system(If needed) Bearings lubrication unit; shaft vibration, shaft displacement, and bearing temperature monitoring probes(As needed)Pressure, temperature, and level display and monitoring electrical instruments for primary elements and secondary signaling elements in various systems(If needed)All internal wiring cables, junction boxes or terminal boxes, conduit pipes, supports and mounting brackets, along with their fasteners within the base range; all connecting piping, pipe fittings, valves, flange joints, etc.; blind flanges, bolts, nuts, and washers for transportation; lifting ring set screws and/Or hanger ears; antistatic conductive mat and/Or grounding pillar; other necessary auxiliary equipment for operations; installation, trial run andOneAnnual operational spare parts; special tools, etc. All electrical and instrument equipment must comply with the hazardous and explosion-proof levels of the area in which they are used. Ensure that no additional parts are needed for installation and reliable, safe operation of the goods.
Horizontal Centrifugal PumpMatching equipment control cabinets and on-site push-button boxes (one controller, one box).
304In the stainless steel on-site control cabinet, space is reserved forPLCThe system's connection terminals are clearly labeled, and complete control drawings are provided for implementation.PLCAutomatic control.
Inverter Configuration Instructions