Technical Description: Low-Speed Flow Controller QJB7.5/4-2500/2-48_News Center Co., Ltd._Du'an Environmental Protection Equipment (Jiangsu) Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Du'an Environmental Protection Equipment (Jiangsu) Co., Ltd.

Environmental equipment, pumps, water treatment systems, mechanical accessori...

Consultation Hotline
025-57523831   13813381829

News Category
  • No Category

Contact Information
  • Contact person:李经理
  • Telephone:025-57523831
  • 邮件:63572853@qq.com
  • 传真:025-57523831
Home > News Center Co., Ltd. > Technical Description: Low-Speed Flow Controller QJB7.5/4-2500/2-48
News Center Co., Ltd.
Technical Description: Low-Speed Flow Controller QJB7.5/4-2500/2-48
Publish Time:2024-03-05        View Count:8        Return to List

Duwan Environmental QJB7.5/4-2500/2-48 Low-Speed Propeller Flow Accelerator Technical Description

Gearbox减速器

All-Copper Winding Motor

Polyester Impeller

2500mm impeller diameter

10 meters of YCW type underwater sealed cable equipped

Guide Rod, Lifting Frame, Type A Bracket, Hand Winch, Chain Hoist


QJBInstallation Instructions for Submersible Flow Pumps

Duwan Environmental Submerged Pump Flow Controllers are installed strictly according to the on-site environment and recommendations, at the locations specified in the drawings. They provide the necessary lubricants for the operation within the manufacturer's suggested warranty period. The foot bolts are supplied and installed by the vendor and should meet the manufacturer's requirements.

Concrete Foundation

The concrete foundation for the mixer is the responsibility of the civil construction supplier. The equipment supplier should coordinate with the civil construction supplier to ensure the foundation is properly positioned. The concrete strength grade should meet the requirements for the mixer's installation and operation, unless otherwise specified, and the foundation bolts should be correctly placed during grouting.

Factory Painting

A.Prior to painting, all equipment surfaces must be thoroughly cleaned and dried, removing grease, rust, dirt, and other surface contaminants.

B.AllSubmersible propellers, motors, and other driving equipment should be coated with an undercoat and finish paint according to this specification in the factory. The surfaces that will come into direct contact with wastewater during operation should be reliably corrosion-resistant treated.

Inspection and Testing

A.Summary

1.Before shipment from the factory, the owner has the right to inspect and test all equipment and materials as per this specification.

2.Prior to shipment, a written notice should be promptly sent to the owner to allow them to schedule an inspection.

3.Duwan Environmental provides the necessary facilities, including personnel, for owners to conduct inspections and tests, and ample time should be allocated for these activities.

4.All materials and equipment should be inspected and tested in accordance with the owner's requirements. Suppliers should anticipate that inspections and tests of materials and equipment may cause delays.

5.Manufacturers' representatives should conduct on-site services to facilitate installation inspections and equipment trial runs.

6.After the installation work and trial preparation are completed, field testing can commence.

B.Mixing Machine

1.Jiangsu Du'an Environmental ProtectionQJBUnder on-site installation guidance for the submersible mixer, all installation work was completed. The trial was conducted in the presence of the owner to ensure the mixer's operation complies with regulatory requirements. On-site testing should provide the necessary water or wastewater, labor, equipment, and temporary facilities to complete the trial.

2.If the mixer's performance does not meet the specifications, it should be replaced. Prior to acceptance, it is mandatory to24Hourly operational test.

C.Motor

1.Suppliers should connect the motor's wiring before the motor is powered on. If the insulation is good, they should notify the owner and proceed with measures approved by the owner.

2.Suppliers should inspect the correct installation of all motors according to the manufacturer's requirements, as well as check the lubrication and the motor's wiring and rotation direction.

Jiangsu Du'an Environmental ProtectionQJBSubmersible mixer and flow driver installation and debugging phase

RoutineThe performance tests should be conducted under normal load conditions.24Hourly.

 

Jiangsu Du'an Environmental Protection Submersible Propeller Model Specifications: 

Transmitter Model

Power

Electric Current

Impeller Diameter

Thrust

Weight

Installed the system

KW

A

mm

N

kg

QJB1.5/4-1100/2-85P

1.5

4

1100

1800

170

System IV

QJB1.5/4-1400/2-36P

1.5

4

1400

800

175

System IV

QJB1.5/4-1800/2-42P

1.5

4

1800

1480

180

System IV

QJB2.2/4-1400/2-42P

2.2

5.3

1400

900

180

System IV

QJB2.2/4-1800/2-42P

2.2

5.3

1800

1100

185

System IV

QJB3/4-1100/2-115P

3

7.2

1100

2200

180

System IV

QJB3/4-1400/2-56P

3

7.2

1400

2000

185

System IV

QJB3/4-1800/2-56P

3

7.2

1800

1800

190

System IV

QJB4/4-1800/2-56P

4

9.2

1800

1700

170

System IV

QJB4/4-1800/2-63P

4

9.2

1800

1800

190

System IV

QJB4/4-2500/2-42P

4

9.2

2500

2900

210

System IV

QJB5/4-2500/2-56P

5

11.9

2500

3100

240

System IV

QJB7.5/4-2500/2-63P

5

15.2

2500

4250

280

System IV

Field Conditions

Equipment Specifications

2500  Pe=7.5kW

1800  Pe=4.3kW

Installation Locations and Quantities

Anoxia Zone12Set

Anaerobic Zone8Set

Single Seat Pool Specifications

View the design diagram

View the design drawing

Water Depthm

6.2

6.3

SSConcentration

4800mg/L

3200mg/L

pH

6~9

6~9

Medium Temperature

0~40

0~40

Overtime policy

24h/day

24h/day

Hanging Bracket

Fixed electric hoists - one-on-one, with additional portable hoists.2Set

B.Technical Performance

Equipment Model

2500   Pe=7.5kW

1800   Pe=4.3kW

Form

Underwater Propulsion System

Underwater Propeller

Propeller Diameter(mm)

D=2500

D=1800

Propeller Blades Count

2

2

Motor Power(kW)

7.5

4.3

Power Supply

380V/3ph/50Hz

380V/3ph/50Hz

Motor Protection Class/Insulation Grade

IP68/H

IP68/H

NoisedB(A)

55

55

Uninterrupted Operating Time

8000Hour

8000Hour

Service Life

20Year

20Year

 



 Click submit means you agree to《Service terms》《Privacy policy》