During the calibration phase, what should be noted for a gas chromatograph?_News Center Co., Ltd._Shandong Jinpu Analytical Instruments Co., Ltd.
欢迎来到Shandong Jinpu Analytical Instruments Co., Ltd.!
  • Sales Hotline:0632-8670986  13181278603


Company Information

Location:Shandong/Zaozhuang

会员级别:采商通4

身份认证:    

我的勋章:  通过中商114认证

Business Card

  • 公司名称Shandong Jinpu Analytical Instruments Co., Ltd.
  • 联 系 人何先生 (先生)
  • 公司电话0632-8670986
  • 手机号码13181278603
  • Company Address199 Yufan 6th Road, High-tech Zone, Zaozhuang City, Shandong Province

更多Product Classification Co., Ltd.
  • No Category

更多Contact Information
  • Contact person:何先生
  • Telephone:0632-8670986
  • Email:1277926230@qq.com
  • Mobile:13181278603
Home > News Center Co., Ltd. > During the calibration phase, what should be noted for a gas chromatograph?
News Center Co., Ltd.
During the calibration phase, what should be noted for a gas chromatograph?
Publish Time:2022-05-20        View Count:14        Return to List

I. In multi-dimensional systems, various tasks can typically be successfully completed without affecting analysis. For systems like gas chromatography columns, it is advisable to avoid disassembly as much as possible. Only the relevant chromatography column systems can achieve more effective connections without detecting any leaks.

Some signals require reasonable collection. In fact, there are significant differences between data collection systems, so this aspect should be paid attention to. In actual calculations, they should be fully corrected. Gas chromatographs can exhibit good sensitivity during operation.

In regards to the探测器, it is necessary to conduct regular effective calibrations to ensure its optimal performance. Toluene should be chosen, as it not only meets the characteristics of low-temperature chromatography columns but also has a relatively faster peak time in specific application processes.

In practical operations, it is impossible to completely avoid sample bias, regardless of the gas chromatography instrument's injection system. Chromatographic analysis is relatively quantitative; as long as the operating parameters and conditions can be consistently reproducible, even with some degree of sample bias, the analysis results will be reproducible. The impact of sample bias on quantitative accuracy can be mitigated through calibration with standard samples.

During the calibration phase, what should be paid attention to with a gas chromatograph?

To ensure the longevity of use for the gas chromatograph, we should pay attention to the following points during operation:

  1. To prevent SiO2 from entering the detector, the chromatographic column must be properly aged, especially for siloxane-based stationary phases, which should have a thin liquid film. Additionally, it is crucial to avoid any SiO2 residue remaining in the sample post derivatization that could enter the chromatographic column.

  2. Prior to shutting off the carrier gas, the voltage of the thermal ion source should be set to 0; otherwise, no carrier gas will pass through, and the rubidium salt bead will burn out within minutes.

  3. Under the condition of meeting sensitivity requirements, use the lowest ion source voltage as possible.

  Ensure to open the gas line first when operating, as heating the column incubator without doing so may damage the column.

  Regularly clean the sample tubes, and replace the quartz wool inside them frequently.

 