Product Details

Temperature Control Range

Maximum temperature error

±0.5°C

Number of samples

3, 4, 6 are optional.

Deformation measurement range

0-12mm

Deformation Measurement Error

0.005 mm

Available Locations

National

XRW Series Heat Deformation and Vicat Softening Point Temperature Controller
Application Scope
主要用于 measuring the heat deflection temperature and Vicat softening point temperature of non-metallic materials such as plastic, hard rubber, nylon, electrical insulating materials, long fiber reinforced composites, and high-strength thermosetting laminates. User-friendly, with precise control, this is an extremely high-intelligent testing instrument, widely used in colleges and universities, research institutions, and product quality supervision and inspection units.
Standard of Execution
  
  
  GB/T 1633、 GB/T 1634 、GB/T 8802 、ISO 2507、 ISO 75、ISO 306、ASTM D 1525、ASTM D 648
  XRW-300B-3
Technical Specifications:
Temperature Control Range: Room temperature to 300℃
2. Maximum temperature error: ±0.5℃
Sample Racks: 3, 4, 6 available options
5. Deformation Measurement Instruments: Micrometer caliper
6. Range of Deformation Measurement: 0~12mm
7. Deformation Measurement Error: 0.005mm
8. Heating Medium: Methyl silicone oil
Cooling Method: Natural cooling above 100℃, water cooling below 100℃.
  
Product Features
5-inch touchscreen operation
Voice Broadcasting Feature
PID Module Control
Automatically calculate test data
Micro Printing Function
  
  XRW-300C-3
  
Technical Specifications:
Temperature Control Range: Room temperature to 300℃
2. Maximum temperature error: ±0.5℃
Sample Racks: Available in 3, 4, or 6 options
5. Deformation Measurement Tools: Micrometer;
6. Range of Deformation Measurement: 0~12mm
7. Deformation Measurement Error: 0.005mm
8. Heating Medium: Methyl silicone oil
Cooling Method: Natural cooling above 100℃, water cooling below 100℃.
  
Product Features
Computer Control System
Sample holder automatic lifting
Automatically calculate test data, store and query