Firstly, gradually adjust the " coarse " button according to the required tension, then slowly adjust the " fine " button to ensure proper coordination. For example, if a 12V voltage output is needed, the " coarse " button must be set to the 15V position, and the " fine " button must be set to the 12V position; otherwise, it will not reach 12V, and the output voltage will not be 12V.
Set the required voltage, then reconnect it to the load.
3. If a change to the " coarse adjustment " setting is required during operation, the load must first be disconnected, the output voltage set to the desired value, and then the load reconnected.
4. In the event of a load short circuit or overload during operation, first disconnect the load, then press the "Restore" button or turn off the power and then back on to restore the voltage to normal operating conditions. After troubleshooting the load, reconnect it. Aviation power 10, 400HZ power 8, aviation ground power 15, 27V DC power.
When串联 connecting power units with different rated currents, the output current must correspond to the rated value of the smaller rated current.
Each power supply features a measuring head that displays the output current or voltage of the channel under different A/V states. Typically, it is set to the voltage indication state.