a) Overvoltage Protection: 1.1Ue ± 0.5V (protects shutdown, restarts upon power-on); b) Overcurrent or current limiting protection, protection value: 1.1Ie ± 1A; c) Undervoltage Protection Value: 0.95Ue ± 1V; d) The module should have temperature protection, with the temperature value specified by the manufacturer. 400Hz Power Supply