Adjust the " coarse " knob first according to the required voltage, then gradually adjust the " fine " knob to achieve proper coordination. For instance, when outputting 12V, set the " coarse " knob to the 15V position, then adjust the " fine " knob to 12V. The " coarse " knob should not be set to the 10V position. Otherwise, the output voltage will not reach 12V.
Adjust the voltage to the required level before connecting the load.Aviation Power Supply
When changing to the " coarse adjustment " gear, the load should be disconnected first, wait until the output voltage is adjusted to the desired value, and then reconnect the load.
During operation, if protection is triggered due to a load short circuit or overload, the load should first be disconnected, then press the "Reset" button. Alternatively, you can also restart the power supply, which will restore normal voltage operation. After the fault is eliminated, reconnect the load.
When using series connections of power sources with different rated currents, the output current is equal to the rating of the path with the lowest rated current.400Hz power supply
Each power line features a meter head, which indicates the output current or voltage of the line respectively in different A/V states. Typically, it is set to the voltage indication state.
Each channel features two output terminals, one red and one black. The red terminal signifies “+”, while the black terminal denotes “-”. The center of the panel has a black terminal with a "ground" symbol, indicating that this terminal connects to the housing and is electrically isolated from each output channel, serving solely as a safety wire. Many people mistakenly assume that the "ground" symbol indicates grounding, with “+” and “-” representing the positive and negative power supply lines going to the dual power supply operational amplifier.
Two-way voltages can be used in series. Parallel usage is not permitted. Power supplies are a measuring instrument for supply quantities, hence the output terminal should not be short-circuited for extended periods.Ground Power Unit for Aviation