详情描述


Lepu Clean Pulse Reverse Blowing Industrial Vacuum Cleaner Technical Specifications

Product Model: LP40FC-1

Rated Voltage: 380V/50Hz

Equipment Power: 4000W

Machine Airflow: 420 m³/h

Machine Suction: 26 KPa

Filtering Area: 92,000 cm²

Noise Level: 69 dB

Dust Collection Capacity: 100L

Cable Length: 5M

Filter Type   Multi-fold Filter

Filter Efficiency 0.3um

Machine Net Weight: 145 kg

Machine Dimensions: 1290*590*1380mm

Lopure LP40FC-1

Pulse Jet Industrial Vacuum Cleaner

Primary Power

Equipped with a three-stage asynchronous turbocharged electric motor, OEM factory made, featuring NSK bearings, capable of continuous 24-hour operation.

2. Machine Structure

Utilizing an upper and lower separated drum design, easy to clean waste inside the drum, with enhanced load-bearing and impact resistance, 2mm thick steel plate, equipped with brake features on the casters for easy movement.

Filter

Utilizing PTFE and HEPA coated filters with a 0.3 micron precision. After prolonged use, the filters can be washed with water, dried, and reused.

4. High-Efficiency Coated Filter

Built-in high-efficiency membrane filter element design, polyester fiber membrane material, equipped with an internal pulse control valve for automatic reverse air cleaning, allowing customizable pulse time intervals, no manual operation required, effectively solving filter clogging issues.

5. Cyclone Separator

Built-in cyclone device; dust just inhaled is separated by the cyclone separator, achieving 99.97% dust separation; 0.03% of the dust will float directly around the drum and on the filter.

6. Pulsed reverse air device

Based on the amount of dust, the pulse interval can be adjusted; the pulse time is automatically cleaned by the pulse valve's cycle interval.

7. Pressure Relief Valve

When the filter becomes clogged, the pressure relief valve automatically opens, allowing air to enter through the valve, thus protecting the motor from overheating and burning out.

8. Electric Control System

Utilizing Schneider brand, featuring leakage, phase failure, overload protection, stable performance, and easy operation.

9. Vacuum Inlet

Utilizing quick-release connectors, 70 to 50 standard fittings; the accessories chosen vary depending on the selected quick connector specifications.