Training Tower_SupplyPro Co., Ltd._Jingxian Huiting Steel Tower Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Jingxian Huiting Steel Tower Co., Ltd.

Monitoring Tower | Observation Tower | Chimney Tower

Consultation Hotline
13315863133

Product Categories
Home > SupplyPro Co., Ltd. > Training Tower
Training Tower
品牌: Huating
Brand: Huiteng
Origin: Hebei
Compressive Strength: Strong
单价: 600.00/Individual
最小起订Quantity: 1 Individual
供货总Quantity: 1000000 Individual
有效期至: 长期有效
最后更新: 2022-02-18 17:12
 
详细Info

The training tower should meet the following requirements:

One, the training tower should be located near the end of the training ground with a reserved runway, and a sand pit of 1.5 meters should be reserved in front of the tower.

The training tower should have at least four floors, and in cities with a high number of high-rise buildings, the number of floors may be appropriately increased.

Section 3: Each floor of the training tower's front has at least two windows, with a width between the windows (and the wall) of 1.0 meter.

Four, the training tower window dimensions are 1.2m x 1.8m, the window must be no less than 0.65m from the tower edge, the window sill width is 0.35m, the sill board thickness is 0.05 (protruding from the tower wall by 5cm), the height from the window sill to the floor of each level is 0.8m, the floor height is 3.5m, and an internal staircase with a clear width of no less than 0.7m should be provided, with a handrail tube diameter of no less than 0.026m.

Five, An unobstructed platform of not less than 1.5 meters wide should be provided on the inner side of each floor of the training tower, with a floor installed at the top level.

Six, it is advisable to install an outdoor fire escape ladder in the training tower. The ladder should lead to the top of the tower and ideally be set at a height of 3 meters above the ground, with a width not less than 50 centimeters. Training Tower Description: 1. Mainly composed of (1) simulated windows, (2) floor partitions, (3) rear frames, (4) observation and command platform frames, and the main steel structural frame. Simulated windows are installed at the front of the tower (custom-made with a specified number of floors and windows as needed), and floor partitions (steel plates) are placed between the upper and lower adjacent simulated windows. 2. A rear frame corresponding to the simulated windows is located at the bottom of the tower. 3. The simulated windows, floor partitions, rear frames, and main frame are bolted together. 4. Each floor is connected with a safety staircase. 5. The upper part of the tower is equipped with an observation and command platform.

Section 7: Training towers typically undergo anti-corrosion treatment with spray painting, in military green. Alternatively, camouflage patterns or galvanizing may be applied.

Section 8: Our steel structure fire training towers are fully functional, featuring detachable and portable designs that are not restricted by geography, terrain, or land plots. Made with assembly components, they offer low cost and high recyclability, thus saving expenses and achieving twice the results with half the effort. Welcome fire departments to order our fire training towers.


询价单
 Click submit means you agree to《Service terms》《Privacy policy》

13315863133