Ductile steel corrugated pipe_SupplyPro Co., Ltd._Hengshui Dinggao Engineering Materials Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》

Ductile steel corrugated pipe

产品Price 330.00/Rice

最小起订Quantity:10 Rice 供货总Quantity: 17000 Rice

用手机扫描二维码直达商品手机版
MobileView details
Location:
Hebei/Hengshui
有效期至:
长期有效
最后更新:
2022-02-27 19:04
Product Details

Brand

Application Site

Tunnel, Tunnel, Arch Bridge

Compressive Strength

375 kp

Waveform

125x25, 150x50, 200x55

Thickness

2-12mm

Available Markets

National

Wavy culvert (plate) advantages: 1. Easy to maintain, simply ensure the protection and maintenance of the inner wall.

Secondly, steel corrugated pipe offers significant economic benefits in frozen soil regions and soft soil roadbed areas.

Section 3: The steel corrugated pipe has been treated for corrosion resistance, offering high durability.

Four, its good overall integrity and plasticity provide strong resistance to deformation in road sections with complex geological conditions.

V. Its excellent thermal conductivity results in minimal disturbance to the subgrade in frozen soil areas, ensuring stability of the subgrade.

Steel corrugated pipe products are available in two structural types: assembled and prefabricated; cross-sectional shapes include circular, elliptical, horseshoe, and arch, etc. The pipe diameter range is 0.3m.

—12m, with a processing thickness of 1.6mm to 7mm, capable of meeting the requirements for structures with a pipe top backfill height of 0.5m to 60m. Wall thickness: refers to the thickness of the steel plate forming the pipe wall.

Diameter: refers to the inner diameter of the corrugated pipe. Generally, for 125-25 wave patterns, 3-Smm steel plates are used; for 200-55 wave patterns, 3-8mm steel plates can be utilized.

Backfill Height: The fill height that a specific model of corrugated culvert can accommodate, for example, a 200-55 corrugated culvert with a wall thickness of 4.5mm can meet the fill height of d2 meters.

Soil height: 0.6-33 meters, meaning the soil thickness above the pipe is 0.6 meters, and the soil thickness is 33 meters. If exceeding 33 meters, the load-bearing capacity can be increased by methods such as increasing the wall thickness.

Power. Vehicles weighing up to 120 tons can pass through the allowed backfill area in increments of k cubic meters. Tunnel Entrance Design: The tunnel entrance is designed as an eight-character wall, as shown in the right figure. Slope Entrance: Due to the culvert and...

Non-90-degree road intersection required for special angle culvert. Culvert slope: Special angle culvert needed due to the use of sloped inlets and outlets.


询价单
主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  
 点击确定代表您同意《服务条款》《隐私政策》
 
 Click submit means you agree to《Service terms》《Privacy policy》

Phone Consultation

Consultation Phone:
18732896953

Back to Top