Biogas ProjectHaiyue Double-Membrane Gas Storage CylinderSix key safety standards including lifespan, leak prevention, surrounding environment, explosion-proof and fire-resistant, distance from high-voltage lines, and project acceptance; for more details, please call 135-8926-0514.
I. Safe Operation Cycle Standard for Haiyue Double Membrane Gas Cabinets:
Our marine gas container is designed with features that include resistance to methane corrosion, UV radiation, and microbial attack. The normal service life exceeds 10-25 years, during which no anti-corrosion treatment is required. All metal connectors are made of stainless steel, capable of withstanding the corrosive environment of the gas container.
Hydropel Double Membrane Gas Storage Vessel Anti-Leakage Safety Standards:
Please provide the Chinese content you would like translated into American English.The gas containers from YUE use materials that meet stringent European standards, with the inner membrane treated with a five-step patented process for weld seams, ensuring the welds' airtightness, physical properties, and lifespan are not less than those of the main material. The outer membrane employs three pressure protection methods, with daily use managed by electronic controls. At YUE...Double Membrane Gas CylinderIn the event of a malfunction, utilize the standby physical pressure relief device to ensure pressure is maintained within a safe range.
Section 3: Environmental Safety Standards for the Haiyue Double-Membrane Biogas Storage Tank
The theoretical wind resistance of the gas storage tank can reach 12 levels; however, strong winds may cause debris to damage the tank. Therefore, when encountering strong winds of level 10 or above, the marine gas storage cabinet must be disabled. Additional lightning protection features should be installed, and additional配套设施 for the biogas project should be purchased.
FourHaiyue Double Membrane Gas Cofferhyhbm.com's biogas gas holder strictly adheres to the design specifications for electrical equipment in explosive and fire hazard environments, GB50058-1992, while employing electrical equipment with D-grade explosion-proof standards according to Q/57463500-5.01-2011.
Five, the high-voltage power lines near the Haiyue Membrane Gas Storage Tank are in compliance with safety standards. The safety distance for a 50kV high-voltage line is to be executed according to regulations, with a distance of no less than 1.5 times the height. For a 220kV line, the distance should be no less than 80 meters. There is a significant amount of induced electricity near high-voltage lines. Short distances may cause instruments to lose control, and the height may exceed the required 1.5 times. For a 500kV line, the distance should be no less than 150 meters. Induced electricity is abundant near high-voltage lines, and short distances may lead to instrument loss of control, with heights exceeding the required 1.5 times.
Six, for the safety acceptance standards of the Haiyue double membrane gas storage cabinets, please use a leak detector to check for methane leakage.