I. Performance Features:

1. Equipped with microcomputer control, the panel features at least 16 touch switches for easy execution of various testing functions. It includes self-check and error reporting capabilities for convenient inspection and maintenance.

2. Comprehensive self-inspection and self-protection features ensure that the circuit can quickly cut off the output and emit both audio and visual alerts during overload or excessive range, reducing unnecessary losses caused by improper operation.

3. Intelligent operation: With just one button, the universal relay's full parameters can be measured, and all data is automatically printed.

4. The display features functional display units, allowing for a clear reflection of the working status from the screen.

5. All printed data is in Chinese characters, such as "Closing Voltage," "Opening Voltage," and "Normal Open Closing Time," etc. (Note: Digital tube display is used without printing functionality).



II. Technical Specifications:

1. Output Voltage Range: Continuously adjustable from 0 to 500V, large output capacity of 6000VA, over-range protection at 500V, with an accuracy of ±0.25%.

AC Current Output

0-50A, 0-100A, 0-200A, 0-600A, continuously adjustable.

At 0-50A, the open circuit voltage is 5V.

At 0-100A, the open circuit voltage is 10V. The overload protection trips at 300A.

From 0 to 200A, from 0 to 600A, the open circuit voltage is 10V.

2. Direct Current Voltage Output:

0-320V continuous adjustable, high current of 2A, over-range protection at 320V.

Overload protection action current: 2.1A ±5%.

3. Direct Current Output:

0-200mA, 0-5A, 0-20A continuously adjustable, with an accuracy of ±0.25%.

At 0-200mA, the open-circuit voltage is 48V, and the overload protection trips at 230mA.

At 0-5A, the open circuit voltage is 24V, and the overload protection trips at 5.2A.

At 0-20A, the open-circuit voltage is 36V.

4. Fixed Direct Current Voltage Output

When outputting 110V or 220V individually, the current can reach up to 2.5A, but in relation to alternating voltage and current,

When DC voltages are output simultaneously, the total capacity cannot exceed 600VA.

5. Digital Millisecond Stopwatch:

Extended Range: 999 seconds (Note: 99.99S)

Resolution: 0.1 millisecond

Accuracy: 0.1% ± 1 character

6. Instrument Accuracy:

Utilizing a 5.5-bit A/D conversion, with an accuracy of 0.05% reading ±1 digit.

7. Overall Measurement Accuracy: ≤0.25%