Below, we introduce to youMung Bean SprouterReason for the Minor Fault and Solutions:
Fault Symptom 1: Screen Not Displaying Possible Causes: 1. Power not connected 2. Function switch not turned on Troubleshooting Methods: 1. Check if the power plug is securely inserted 2. Set the function switch to the "On" position
Fault Symptom Two: Heating tube does not heat up Possible Causes: 1. Damaged or poor contact of heating control components 2. Burnt-out heating tube 3. Loose connectors Troubleshooting Methods: 1. Replace the AC contactor or secure it 2. Replace the heating tube 3. Repair the connector
Fault Symptom Three: No Spraying Possible Causes: 1. Faulty Timing Relay 2. Damaged or Poorly Connected Actuator Switch 3. Loose Spraying Line Connector Troubleshooting Methods: 1. Replace the Timing Relay 2. Replace the Switch or AC Contact 3. Repair the Connector
Fault Symptom Four: Overcurrent protector frequently trips. Possible Causes: 1. Electric leakage in the pump 2. Electric leakage in the heating tube 3. Electric leakage in the body. Solutions: 1. Repair the pump and related wiring 2. Replace the heating tube 3. Inspect and repair the wiring and contact devices in the housing.
The above introduces...Reason for and Solution to Mini-Failure of Sprouter, Hope Everyone Is Informed. For more information, please visit: www.douyajixiewang.com