Below, we introduce to youMung Bean SprouterReason for the Minor Fault and Solutions:

 Fault Symptom 1: Screen Not Displaying Possible Causes: 1. Power not connected 2. Function switch not turned on Troubleshooting Methods: 1. Check if the power plug is securely inserted 2. Set the function switch to the "On" position

Fault Symptom Two: Heating tube does not heat up Possible Causes: 1. Damaged or poor contact of heating control components 2. Burnt-out heating tube 3. Loose connectors Troubleshooting Methods: 1. Replace the AC contactor or secure it 2. Replace the heating tube 3. Repair the connector

Fault Symptom Three: No Spraying Possible Causes: 1. Faulty Timing Relay 2. Damaged or Poorly Connected Actuator Switch 3. Loose Spraying Line Connector Troubleshooting Methods: 1. Replace the Timing Relay 2. Replace the Switch or AC Contact 3. Repair the Connector

Fault Symptom Four: Overcurrent protector frequently trips. Possible Causes: 1. Electric leakage in the pump 2. Electric leakage in the heating tube 3. Electric leakage in the body. Solutions: 1. Repair the pump and related wiring 2. Replace the heating tube 3. Inspect and repair the wiring and contact devices in the housing.