Mining Rubber Sheathed Cable
Rated voltage 0.66/1.14KV and below coal mining machine flexible cables (GB12972.2-91)
This product is suitable for copper-core rubber-insulated sheathed flexible cables used in coal mining machines and similar equipment with rated voltage Uo/1.14V and below.
UC-0.38/0.66: Coal mining machine rubber sheathed flexible cables, power connections for coal mining machines and similar equipment rated at 0.38/0.66KV for use in coal mines
(MCP) UCP-0.38/0.66: Coal mining machine sheathed rubber-sheathed flexible cables, power connections for coal mining machines and similar equipment rated for 0.38/0.66KV voltage for use in coal mines
MCP UCP-0.66/1.14: Coal mining machine shielded rubber-sheathed flexible cables, power connections for coal mining machines and similar equipment rated at 0.66/1.14KV for use in coal mines.
The usage characteristics of coal mining electrical cables and wires
The rated voltage Uo/U is 0.38/0.66KV and 0.66/1.14KV, respectively.
2. The long-term allowable working temperature for the cable conductor is 65°C.
The cable's bend radius is six times the diameter of the wire.
Yellow sleeves should not be exposed to direct sunlight for extended periods.
MY-0.38/0.66 Mining Mobile Rubber Sheathed Flexible Cable - Power Connection Lines for Various Mobile Electrical Appliances in Mining Shafts
MYP-0.38/0.66 Mining Mobile Shielded Rubber Sheathed Cable
The MYP-0.66/1.14 Coal Mine Mining Machine Rubber Sheathed Cable is designed for connecting power sources for underground coal mining machines and similar equipment. It complies with the MT818 standard.
Mine drilling cable is the connecting line for the power supply of electric drills underground. Coal mine electric drills (shielded) rubber sheathed flexible cables comply with standard MT818.8-1999, MZ, MZP-0.3/0.5KV, finished product test voltage 2000V/5min, cross-sectional area 2.5, 4.
The conductors of mining drill cable are tin-coated copper wires, with natural butyl rubber as the insulation material and chlorinated polyethylene as the sheath. It features oil resistance, flame retardancy, shock resistance, and tear resistance. The following table provides a detailed description of the mining drill cable:
Model Name Main Application Scope
MZ-0.3/0.5 Coal Mine Power Drill Cable – Wiring for Power Drills in Underground Mines
MZP-0.3/0.5 Coal Mine Electric Drilling Shielded Rubber Sheathed Cable
MYPTJ Metal Sheathed Monitoring Type Flexible Cables, rated voltage 8.7/10kV and below, for use
Power connections for underground mobile transformers and similar equipment rated for voltages of 8.7/10kV and below.
2. Working Conditions
2.1 Rated voltage U0/U: 3.6/6kV, 6/10kV, 8.7/10kV.
2.2 The long-term allowable working temperature for the cable conductor is 90°C.
2.3 The bend radius of the cable is six times the diameter of the cable.
2.4 The earth core of the cable must be properly grounded.