Duwan Environmental QJB2.2/8-320/3-740S Submersible Agitator
Sludge Pond Submersible Mixers Specifications and Models
QJB Submersible Mixer Quotation
Applicable Voltage: 380V
Motor Power: 2.2 kW
Impeller Diameter: 320mm
Impeller Speed: 740 RPM
Material: 304 Stainless Steel


Du'an Environmental ProtectionQJB2.2/8-320/3-740SDivingAgitatorMachineRuns smoothly without vibration. All rotating parts (including the motor) should undergo dynamic and static balance tests during manufacturing.
Diving mixerMain Material Requirements
Propeller: Stainless Steel AISI304
Motor housing: Stainless steel 304
Axle Stainless Steel 431
Mechanical Seal: Corrosion-resistant Sintered Tungsten CarbideCorrosion-resistant sintered tungsten carbide
Fasteners: Stainless Steel AISI 304
Cable jacket: Neoprene
O-ring: Nitrile rubber or fluoro rubber seal or fluoro rubber
DivingStirrer Bracket: Stainless Steel AISI 304
Guide System: Stainless Steel AISI 304
Chain Lifting Stainless Steel AISI 304
Lifting Device Boom: Stainless Steel AISI304
Chemical Anchor Bolts: Stainless Steel AISI304
Surface Corrosion Protection: Two-component epoxy resin coating, each primer layer is two layers thickOver 1mm, with a surface paint thickness of over 1mm.
Diving mixerMatching stainless steelField Control Box
The on-site control box for the supplied equipment should be technologicallyFrontierProven safe and reliable in actual operation, meeting all design specifications and conforming to general electrical technical requirements.
Each set of submersible mixer comes with a local control box.


Field control box requirements are as follows:
(1) Equipped with push buttons and signal lights; all control boxes have signal lights统一 colored red for stop, green for operation, yellow for fault, and blue for power indication.
(2) Order a matching converter for motor protection with the equipment.
(3) The start/stop button should have two pairs of contacts, and the emergency stop button (with a mushroom head) should remain engaged when pressed.
(4) Terminals use wire terminals.
(5) With cable connector.
(6) Protection Class: IP65.
(7) Reserve PLC interfaces; each equipment requires control from both the local control cabinet and the central control room.
(8) A 3P-32A circuit breaker must be left within the on-site control line and properly wired for the owner's future maintenance of the temporary power connection.
(9) The control box should have ventilation louvers on both sides and a cooling fan installed at the bottom.