QJB3/8-400/3-740S Submersible Agitator Variable Frequency Control
Duwan Environmental Protection Submersible Mixing Pump Installation Diagram
Motor Power: 3 kW
Impeller Speed: 740 RPM
Impeller Diameter: 400mm
Main unit in wooden case packaging

Duwan Environmental QJB3/8-400/3-740S SubmersibleAgitatorMachineRuns smoothly without vibration. All rotating parts (including the motor) should undergo dynamic and static balance tests during manufacturing.
Diving mixerMain material requirements
Propeller: Stainless Steel AISI304
Motor housing: Stainless steel 304
Axle Stainless Steel 431
Mechanical Seal: Corrosion-resistant Sintered Tungsten CarbideCorrosion-Resistant Sintered Tungsten Carbide
Fasteners: Stainless Steel AISI 304
Cable Sheath: Neoprene
O-ring: Nitrile rubber or fluororubber compound or fluororubber
DivingStirrer Bracket: Stainless Steel AISI 304
Guideway system: Stainless steel AISI 304
Chain Lifting Stainless Steel AISI 304
Lifting Device Boom: Stainless Steel AISI304
Chemical Anchor Bolts: Stainless Steel AISI304
Surface Corrosion Protection: Two-component epoxy resin coating, two layers of primer, each with a thicknessOver 1mm, with a surface paint thickness of over 1mm.
Diving AgitatorMatching stainless steelField control box
The equipment supplied should be accompanied by a field control box that is technologically equipped.FrontierProven safe and reliable in actual operation, it meets all design specifications and conforms to general electrical technical requirements.
Duwan Environmental provides a local control box with each set of submersible mixer.




Submersible mixer field control box requirements are as follows:
(1) Equipped with buttons and signal lights; all control boxes feature unified signal lights indicating red for stop, green for operation, yellow for fault, and blue for power.
(2) Purchase a conversion transformer for motor protection, to be ordered with the equipment.
(3) The start/stop button should have two sets of contacts, and the emergency stop button (with a mushroom head) should remain engaged when pressed.
(4) Terminals are of the wire terminal type.
(5) With cable connectors.
(6) Protection Level: IP65.
(7) Reserved PLC interface; each equipment requires control at both the on-site control cabinet and the central control room.
(8) A 3P-32A circuit breaker must be left within the on-site control line and properly wired for the owner's future maintenance of temporary power connections.
(9) Ventilation louvers should be provided on both sides of the control box, and a cooling fan should be installed at the bottom.
Submersible mixer accessories and materials
Two-year warranty period for spare parts with normal operationInventory List;Configuration parameters; flow field diagrams; selection reports; equipment size drawings; main equipment characteristics; performance guarantee letters, and other relevant materials.