G30-1 & G30-2 Variable Frequency Drive Screw Pumps
304 Stainless Steel Screw Pump
316 Stainless Steel Screw Pump Quotation

Screw PumpDesign and installation conditions are detailed in the following data table:
Equipment Name Equipment Description | Equipment Tag Equipment No. | Quantity Quantity | Version Number Rev No. | Page Number Page No. |
Sludge Thickening Pond Sludge Pumps | P110A/B | 2 | A | 1 of 1 |
Project Name Project Title | Project Code Project No. | Item Project Area | ||
B9282 | 110 | |||
Technical Parameters and RequirementsTECHNICAL ConDITIONS / REQUIREMENTS | ||||
ElevationHeight | 5.9m | |||
High/Low Environmental Temperature Max. /Min. /Ambient Temperature | 38.5℃/-14.7℃ | |||
Installation EnvironmentEnvironment | Treated Sludge Concentration Pond Surface | |||
Fluid conditionsFluid | ||||
Descriptioncription | Sludge thickening pond sludge | |||
High/Low Temperature - Max/Min | Room temperature | |||
- solids coSolids Content % | 1 | |||
Specific Gravity | 1.1 | |||
Corrosion | pH6~9,DurableCorrosion | |||
PumpPump | ||||
Manufacturer Manufacturer | Suppliervender | |||
Type type | Integrated | |||
ModelModel Number | Suppliervender | |||
Driverdriver | MotorElectric motor | |||
Rated Flow Ratem3/h rated capacity | 25 | |||
Rated Headm rated total head | 30 | |||
With or without base?mounting | Isyes | |||
Operation Statusavailability | Intermittent operationIntermittent operation | |||
System Operation Statussystem operation | 2 units, one for use and one as a backup | |||
Efficiency% Efficiency | 85% | |||
Shaft PowerkW Absorbed Shaft Power | 11KW | |||
Erosion Reserve m NPSH required | Duwan Environmental Protection | |||
Material Construction Material | ||||
Pump housing, base | HT200 | |||
Stator | Nitrile Rubber | |||
Rotor | SS316L | |||
- Connecting shaft, drive shaft | SS316L | |||
Axial Seal | Mechanical Seal | |||
Pump and drive connection method Drive Coupling Make | Direct Connection | |||
Import/Export Suction and Discharge | Vertical input, horizontal output | |||
Inlet Flange DimensionsGrade / Flange Inlet Size/Rating | Inlet flange dimensionsDN125, PN10, face meets HG/T20592-2009, PN10; if not, please provide the matching flange. | |||
Export Flange DimensionsGrade / Discharge Size/Rating | Export Flange DimensionsDN100, PN10, face meets HG/T20592-2009, PN10; if not, please provide matching flange. | |||
Motor Motor | ||||
Variable Frequency Motor | Certainly | |||

Motor Power: 2.2 kW
Motor Power: 3 kW
Duwan Environmental ProtectionG TypeScrew pumpManufacture, inspection, testing, and acceptance
Duwan Environmental Protection specializes in screw pumps.Establish a comprehensive quality inspection system to ensure that all factors affecting product safety, reliability, operational performance, and long-term operational performance have been considered, and that necessary tests, inspections, and calibrations are conducted on processing, inspection, and testing equipment.
Sludge screw pump manufacturing, inspection, testing, and acceptance should be conducted in accordance with relevant standards, specifications, and regulations. The seller should note that these requirements do not replace the internal quality assurance measures of the manufacturing plant. The seller shall submit the required inspection, testing results, and records for the buyer's approval.
Inspect materials used for manufacturing sludge screw pumps and issue material factory pass certificate, material inspection and test records.
In accordance with the requirements of relevant standards, specifications, and regulations, static and dynamic balancing tests are conducted on the main rotating components of the pump.
All pressure-bearing components of the screw pump, including the cooling jacket, must be statically tested in accordance with regulations within the manufacturer's workshop, with the static test pressure not less than the closed lift (zero flow).Twice and should not be less than 0.2 MPa.
Under the specified test pressure, no part of the pump shall exhibit deformation or signs of deformation, nor shall any other defects be present. The performance tests of the sludge screw pump and the motor should be conducted in accordance with the requirements of the relevant standards, and the allowable deviations of all indicators should comply with the relevant standards.
For the pumps supplied, the performance curve should start from the closed-end point (zero flow) and extend at least to the rated flow point.130%, and should include the following: pump position number, pump model and specifications, test speed, test medium and temperature, performance curves, design operating conditions.
During testing of the screw pumps supplied, the mechanical seal provided with the contracted equipment should be used.
In addition to the见证试验 projects specified by the buyer, inspections of the ordered equipment materials, manufacturing, and packaging can be conducted at any time during the entire manufacturing process. During the inspection,Manufacturer to customerProvide all drawings and documentation for processing and assembly, inspection tools and equipment, as well as relevant standards and specifications for equipment manufacturing and inspection, to facilitateUserConduct inspections.
Upon completion of the inspection, all drawings, documentation, inspection tools, and applicable standards shall be returned to the manufacturing facility.
Painting the equipment surface is not permitted until all inspection work is completed.
The original records of inspections and tests are to be retained by the seller for five years from the date of shipment of the equipment.